Datasheet

LT3482
3
3482fa
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device reli-
ability and lifetime.
PARAMETER CONDITIONS MIN TYP MAX UNITS
SHDN Voltage Low 0.4 V
SHDN Pin Bias Current 35 50 µA
f
SET
Voltage High 1.5 V
f
SET
Voltage Low 0.4 V
f
SET
Bias Current f
SET
= 2V 22 40 µA
CTRL to FB Offset CTRL = 0.5V
–5
–10
2
2
10
15
mV
mV
APD Current Monitor Gain I
APD
= 250nA, 10V ≤ MONIN ≤ 90V
I
APD
= 2.5mA, 20V ≤ MONIN ≤ 90V
0.180
0.185
0.20
0.20
0.215
0.215
Monitor Output Voltage Clamp 11.5 V
APD Monitor Voltage Drop MONIN – APD at I
APD
= 1mA, MONIN = 90V 5 V
MONIN Pin Current Limit APD = 0V, MONIN = 40V 15 mA
The denotes the specifi cations which apply over the full operating
temperature range, otherwise specifi cations are at T
A
= 25°C. V
IN
= 3V, V
S
H
D
N
= 3V unless otherwise noted.
ELECTRICAL CHARACTERISTICS
Note 2: The LT3482E is guaranteed to meet specifi ed performance from
0°C to 85°C. Specifi cations over the –40°C to 85°C operating temperature
range are assured by design, characterization and correlation with statisti-
cal process controls. The LT3482I is guaranteed to meet performance
specifi cations over the –40°C to 125°C operating temperature range.
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.