Datasheet
LT3470
15
3470fd
applicaTions inForMaTion
Figure 6. A Well Chosen Input Network Prevents Input Voltage Overshoot and
Ensures Reliable Operation When the LT3470 Is Connected to a Live Supply
+
LT3470
2.2µF
V
IN
10V/DIV
I
IN
10A/DIV
10µs/DIV
V
IN
CLOSING SWITCH
SIMULATES HOT PLUG
I
IN
(6a)
(6b)
(6c)
LOW
IMPEDANCE
ENERGIZED
24V SUPPLY
STRAY
INDUCTANCE
DUE TO 6 FEET
(2 METERS) OF
TWISTED PAIR
+
LT3470
2.2µF
10µF
35V
AI.EI.
LT3470
2.2µF0.1µF
1Ω
3470 F06