Datasheet

LT3014
12
3014fd
TYPICAL APPLICATIONS
5V Buck Converter with Low Current Keep Alive Backup
Buck Converter
Effi ciency vs Load Current
BOOST
V
IN
6
2
10
12
D1
10MQ060N
R1
15.4k
V
OUT
5V
1A/20mA
4
15
14
11
C
C
1nF
FOR INPUT VOLTAGES BELOW 7.5V,
SOME RESTRICTIONS MAY APPLY
INCREASE L1 TO 30μH FOR LOAD
CURRENTS ABOVE 0.6A AND TO
60μH ABOVE 1A
1, 8, 9, 16
LT1766
SHDN
SYNC
SW
BIAS
FB
V
C
GND
C2
0.33μF
C1
100μF 10V
SOLID
TANTALUM
L1
†
15μH
D2
D1N914
R2
4.99k
3014 TA03
C3
4.7μF
100V
CERAMIC
V
IN
5.5V*
TO 60V
+
ADJ
3.92M
1.27M
OUTIN
SHDN
LT3014
GND
OPERATING
CURRENT
HIGH
LOW
*
†
LOAD CURRENT (A)
0
EFFICIENCY (%)
80
90
100
1.00
3014 TA04
70
60
50
0.25
0.50
0.75
1.25
V
IN
= 10V
V
IN
= 42V
V
OUT
= 5V
L = 68μH
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.