SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
Error Amplifier Clamp Voltage High Clamp, V
FB
= 1V 1.5 1.8 2.30 V
Low Clamp, V
FB
= 1.5V 0.2 0.3 0.52 V
A
V
Error Amplifier Voltage Gain 500 V/ V
V
C
Pin Threshold Duty Cycle = 0% 0.9 1.1 1.35 V
f Switching Frequency 2.7V V
IN
25V 460 500 550 kHz
0°C T
J
125°C 440 500 580 kHz
–40°C T
J
0°C (I-Grade) 400 580 kHz
Maximum Switch Duty Cycle 85 95 %
Switch Current Limit Blanking Time 130 300 ns
BV Output Switch Breakdown Voltage LT1370 35 44 V
LT1370HVC, 0°C T
J
125°C 42 47 V
LT1370HVI, – 40°C T
J
0°C (I-Grade) 40 V
V
SAT
Output Switch ON Resistance I
SW
= 6A 0.065 0.11
I
LIM
Switch Current Limit Duty Cycle = 50% 6810A
Duty Cycle = 80% (Note 1) 7 A
I
IN
Supply Current Increase During Switch ON Time 22 33 mA/A
I
SW
Control Voltage to Switch Current 10 A/V
Transconductance
Minimum Input Voltage 2.4 2.7 V
I
Q
Supply Current 2.7V V
IN
25V 4.5 6 mA
Shutdown Supply Current 2.7V V
IN
25V, V
S/S
0.6V 12 40 µA
Shutdown Threshold 2.7V V
IN
25V 0.6 1.3 2 V
Shutdown Delay 41225µs
S/S Input Current 0V S/S 5V –7 10 µA
Synchronization Frequency Range 600 800 kHz
E
LECTR
IC
AL C CHARA TERIST
ICS
V
IN
= 5V, V
C
= 0.6V, V
FB
= V
REF
, V
SW
, S/S and NFB pins open, T
A
= 25°C unless otherwise noted.
The denotes specifications which apply over the full operating
temperature range.
Note 1: For duty cycles (DC) between 45% and 85%, minimum switch
current limit is given by I
LIM
= 2.65(2.7 – DC).