5
LT1355/LT1356
SYMBOL PARAMETER CONDITIONS V
SUPPLY
MIN TYP MAX UNITS
ELECTRICAL CHARACTERISTICS
V
OUT
= ±2.5V, R
L
= 150Ω±5V ● 0.4 V/mV
V
OUT
= ±1V, R
L
= 500Ω±2.5V ● 1.7 V/mV
V
OUT
Output Swing R
L
= 1k, V
IN
= ±40mV ±15V ● 13.0 ±V
R
L
= 500Ω, V
IN
= ±40mV ±15V ● 11.5 ±V
R
L
= 500Ω, V
IN
= ±40mV ±5V ● 3.4 ±V
R
L
= 150Ω, V
IN
= ±40mV ±5V ● 2.6 ±V
R
L
= 500Ω, V
IN
= ±40mV ±2.5V ● 1.2 ±V
I
OUT
Output Current V
OUT
= ±11.5V ±15V ● 23.0 mA
V
OUT
= ±2.6V ±5V ● 17.3 mA
I
SC
Short-Circuit Current V
OUT
= 0V, V
IN
= ±3V ±15V ● 23 mA
SR Slew Rate A
V
= –2, (Note 4) ±15V ● 120 V/µs
±5V
● 50 V/µs
GBW Gain Bandwidth f = 200kHz, R
L
= 2k ±15V ● 7.0 MHz
±5V
● 5.5 MHz
Channel Separation V
OUT
= ±10V, R
L
= 500Ω±15V ● 98 dB
I
S
Supply Current Each Amplifier ±15V ● 1.50 mA
Each Amplifier ±5V ● 1.45 mA
Note 1: Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired.
Note 2: Differential inputs of ±10V are appropriate for transient operation
only, such as during slewing. Large, sustained differential inputs will cause
excessive power dissipation and may damage the part. See Input
Considerations in the Applications Information section of this data sheet
for more details.
Note 3: A heat sink may be required to keep the junction temperature
below absolute maximum when the output is shorted indefinitely.
Note 4: Slew rate is measured between ±10V on the output with ±6V input
for ±15V supplies and ±1V on the output with ±1.75V input for ±5V
supplies.
TYPICAL PERFORMANCE CHARACTERISTICS
U
W
Input Common Mode Range vs
Supply Voltage
Supply Current vs Supply Voltage
and Temperature
SUPPLY VOLTAGE (±V)
V
–
COMMON MODE RANGE (V)
2.0
0.5
1.0
1.5
V
+
–1.0
–0.5
–2.0
–1.5
10501520
1355/1356 G02
T
A
= 25°C
∆V
OS
< 1mV
Input Bias Current vs
Input Common Mode Voltage
INPUT COMMON MODE VOLTAGE (V)
–50
INPUT BIAS CURRENT (nA)
0
200
150
100
50
–15 –10 0 10 155–5
1355/1356 G03
V
S
= ±15V
T
A
= 25°C
I
B
=
I
B
+
+ I
B
–
————
2
Note 5: Full power bandwidth is calculated from the slew rate
measurement: FPBW = (SR)/2πV
P
.
Note 6: This parameter is not 100% tested.
Note 7: The LT1355C/LT1356C are guaranteed functional over the
operating temperature range of –40°C to 85°C.
Note 8: The LT1355C/LT1356C are guaranteed to meet specified
performance from 0°C to 70°C. The LT1355C/LT1356C are designed,
characterized and expected to meet specified performance from –40°C to
85°C, but are not tested or QA sampled at these temperatures. For
guaranteed I-grade parts, consult the factory.
The ● denotes the specifications which apply over the temperature range
–40°C ≤ T
A
≤ 85°C, V
CM
= 0V unless otherwise noted. (Note 8)
SUPPLY VOLTAGE (±V)
0.4
SUPPLY CURRENT (mA)
0.8
0.6
1.4
1.2
1.0
10501520
1355/1356 G01
–55°C
25°C
125°C