Datasheet

3
LT1207
V
CM
= 0, ±5V V
S
±15V, pulse tested, V
SHDN A
= 0V, V
SHDN B
= 0V, unless otherwise noted.
ELECTRICAL CHARACTERISTICS
SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
Noninverting Input Current V
S
= ±5V to ±15V 30 500 nA/V
Power Supply Rejection
Inverting Input Current V
S
= ±5V to ±15V 0.7 5 µA/V
Power Supply Rejection
A
V
Large-Signal Voltage Gain V
S
= ±15V, V
OUT
= ±10V, R
L
= 50 55 71 dB
V
S
= ±5V, V
OUT
= ±2V, R
L
= 25 55 68 dB
R
OL
Transresistance, V
OUT
/I
IN
V
S
= ±15V, V
OUT
= ±10V, R
L
= 50 100 260 k
V
S
= ±5V, V
OUT
= ±2V, R
L
= 25 75 200 k
V
OUT
Maximum Output Voltage Swing V
S
= ±15V, R
L
= 50, T
A
= 25°C ±11.5 ±12.5 V
±10.0 V
V
S
= ±5V, R
L
= 25, T
A
= 25°C ±2.5 ±3.0 V
±2.0 V
I
OUT
Maximum Output Current R
L
= 1 250 500 1200 mA
I
S
Supply Current per Amplifier V
S
= ±15V, V
SHDN
= 0V, T
A
= 25°C2030mA
35 mA
Supply Current per Amplifier, V
S
= ±15V, T
A
= 25°C1217mA
R
SHDN
= 51k (Note 4)
Positive Supply Current V
S
= ±15V, V
SHDN A
= 15V, V
SHDN B
= 15V 200 µA
per Amplifier, Shutdown
Output Leakage Current, Shutdown V
S
= ±15V, V
SHDN
= 15V, V
OUT
= 0V 10 µA
SR Slew Rate (Note 5) A
V
= 2, T
A
= 25°C 400 900 V/µs
Differential Gain (Note 6) V
S
= ±15V, R
F
= 560, R
G
= 560, R
L
= 30 0.02 %
Differential Phase (Note 6) V
S
= ±15V, R
F
= 560, R
G
= 560, R
L
= 30 0.17 DEG
BW Small-Signal Bandwidth V
S
= ±15V, Peaking 0.5dB 60 MHz
R
F
= R
G
= 620, R
L
= 100
V
S
= ±15V, Peaking 0.5dB 52 MHz
R
F
= R
G
= 649, R
L
= 50
V
S
= ±15V, Peaking 0.5dB 43 MHz
R
F
= R
G
= 698, R
L
= 30
V
S
= ±15V, Peaking 0.5dB 27 MHz
R
F
= R
G
= 825, R
L
= 10
Note 3: Thermal resistance θ
JA
varies from 40°C/W to 60°C/W depending
upon the amount of PC board metal attached to the device. θ
JA
is specified
for a 2500mm
2
test board covered with 2oz copper on both sides.
Note 4: R
SHDN
is connected between the Shutdown pin and ground.
Note 5: Slew rate is measured at ±5V on a ±10V output signal while
operating on ±15V supplies with R
F
= 1.5k, R
G
= 1.5k and R
L
= 400.
Note 6: NTSC composite video with an output level of 2V.
The
denotes specifications which apply for 0°C T
A
70°C.
Note 1: Applies to short circuits to ground only. A short circuit between
the output and either supply may permanently damage the part when
operated on supplies greater than ±10V.
Note 2: Commercial grade parts are designed to operate over the
temperature range of –40°C to 85°C but are neither tested nor guaranteed
beyond 0°C to 70°C. Industrial grade parts tested over –40°C to 85°C are
available on special request. Consult factory.