Datasheet

4
LT1170/LT1171/LT1172
117012ff
SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
Flyback Amplifier Source V
C
= 0.6V Source 15 32 70 µA
and Sink Current I
FB
= 50µASink 25 40 70 µA
BV Output Switch Breakdown 3V V
IN
V
MAX
, LT1170/LT1171/LT1172 65 90 V
Voltage I
SW
= 1.5mA LT1170HV/LT1171HV/LT1172HV 75 90 V
LT1172S8 60 80 V
V
SAT
Output Switch LT1170 0.15 0.24
“On” Resistance (Note 3) LT1171
0.30 0.50
LT1172 0.60 1.00
Control Voltage to Switch LT1170 8 A/V
Current Transconductance LT1171 4 A/V
LT1172 2 A/V
I
LIM
Switch Current Limit (LT1170) Duty Cycle = 50% T
J
25°C 510A
Duty Cycle = 50% T
J
< 25°C 511A
Duty Cycle = 80% (Note 4) 410A
(LT1171) Duty Cycle = 50% T
J
25°C 2.5 5.0 A
Duty Cycle = 50% T
J
< 25°C 2.5 5.5 A
Duty Cycle = 80% (Note 4) 2.0 5.0 A
(LT1172) Duty Cycle = 50% T
J
25°C 1.25 3.0 A
Duty Cycle = 50% T
J
< 25°C 1.25 3.5 A
Duty Cycle = 80% (Note 4)
1.00 2.5 A
I
IN
Supply Current Increase 25 35 mA/A
I
SW
During Switch On-Time
f Switching Frequency 88 100 112 kHz
85 115 kHz
DC
MAX
Maximum Switch Duty Cycle 85 92 97 %
Shutdown Mode 3V V
IN
V
MAX
100 250 µA
Supply Current V
C
= 0.05V
Shutdown Mode 3V V
IN
V
MAX
100 150 250 mV
Threshold Voltage
50 300 mV
Flyback Sense Delay Time (Note 5) 1.5 µs
The denotes the specifications which apply over the full operating tem-
perature range, otherwise specifications are at T
A
= 25°C. V
IN
= 15V, V
C
= 0.5V, V
FB
= V
REF
, output pin open, unless otherwise noted.
ELECTRICAL CHARACTERISTICS
Transformer designs will tolerate much higher input voltages because
leakage inductance limits rate of rise of current in the switch. These
designs must be evaluated individually to assure that current limit is well
controlled up to maximum input voltage.
Boost mode designs are never protected against output shorts because
the external catch diode and inductor connect input to output.
Note 3: Measured with V
C
in hi clamp, V
FB
= 0.8V. I
SW
= 4A for LT1170,
2A for LT1171, and 1A for LT1172.
Note 4: For duty cycles (DC) between 50% and 80%, minimum
guaranteed switch current is given by I
LIM
= 3.33 (2 – DC) for the LT1170,
I
LIM
= 1.67 (2 – DC) for the LT1171, and I
LIM
= 0.833 (2 – DC) for the
LT1172.
Note 5: Minimum input voltage for isolated flyback mode is 7V. V
MAX
=
55V for HV grade in fully isolated mode to avoid switch breakdown.
Note 1: Absolute Maximum Ratings are those values beyond which the life
of the device may be impaired.
Note 2: Minimum effective switch “on” time for the LT1170/71/72 (in current
limit only) is 0.6µs. This limits the maximum safe input voltage during an
output shorted condition. Buck mode and inverting mode input voltage during
an output shorted condition is limited to:
V
IN
(max, output shorted) = 15V +
buck and inverting mode
R = Inductor DC resistance
I
L
= 10A for LT1170, 5A for LT1171, and 2.5A for LT1172
Vf = Output catch diode forward voltage at I
L
t = 0.6µs, f = 100kHz switching frequency
Maximum input voltage can be increased by increasing R or Vf.
External current limiting such as that shown in AN19, Figure 39, will
provide protection up to the full supply voltage rating. C1 in Figure 39
should be reduced to 200pF.
(R)(I
L
) + Vf