Datasheet

4
LT1017/LT1018
10178fe
LT1017 LT1018
PARAMETER CONDITIONS MIN TYP MAX MIN TYP MAX UNITS
Leakage Current V
S
= 5V, V
OUT
= 40V 25°C 0.5 3 1 8 µA
V
IN
100mV 0.6 3 1.8 10 µA
125°C5 15µA
Supply Current V
S
= 5V 25°C 30 60 110 250 µA
40 80 110 250 µA
125°C 80 300 µA
V
S
= 40V 25°C 40 90 130 250 µA
55 100 140 270 µA
125°C 100 300 µA
Minimum Operating Voltage I
OUT
= 1mA 25°C 1.15 1.2 V
1.15 1.2 V
125°C 1.15 1.2 V
Note 1: Absolute Maximum Ratings are those values beyond which the life
of the device may be impaired.
Note 2: Offset voltage is guaranteed over a common mode voltage range
of V
V
IN
(V
+
– 0.9V).
E
LECTR
IC
AL C CHARA TERIST
ICS
The denotes specifications which apply over the operating temperature
range of –55°C to 85°C for M grade parts, – 40°C to 85°C for I grade parts and 0°C to 70°C for C grade parts.