Datasheet

11
LT1086 Series
APPLICATIONS INFORMATION
WUU
U
device so that heat can flow out the bottom of the case will
significantly lower thermal resistance ( a factor of 2). If
the case of the device must be electrically isolated, a
thermally conductive spacer can be used as long as its
added contribution to thermal resistance is considered.
Note that the case of all devices in this series is electrically
connected to the output.
In both cases the junction temperature is below the
maximum rating for the respective sections, ensuring
reliable operation.
Junction-to-case thermal resistance for the K and T pack-
ages is specified from the IC junction to the bottom of the
case directly below the die. This is the lowest resistance
path for heat flow. While this is also the lowest resistance
path for the H package, most available heat sinks for this
package are of the clip-on type that attach to the cap of the
package. The data sheet specification for thermal resis-
tance for the H package is therefore written to reflect this.
In all cases proper mounting is required to ensure the best
possible heat flow from the die to the heat sink. Thermal
compound at the case-to-heat sink interface is strongly
recommended. In the case of the H package, mounting the
V
IN
6.5V 5V AT 1.5A
*REQUIRED FOR STABILITY
LT1086
LT1086 • AI02
10µF*
TANTALUM
121
1%
365
1%
+
10µF
+
5V, 1.5A Regulator
TYPICAL APPLICATIONS
U
SCSI-2 Active Termination
10µF
TANTALUM
4.25V
TO 5.25V
1N5817
LT1086-2.85
TERMPWR
LT1086 • TA03
10µF
TANTALUM
0.1µF
CERAMIC
18 TOTAL
110
2%
110
110
110
110
2%
110
2%
++
1.2V to 15V Adjustable Regulator
IN
OUT
ADJ
R2
5k
C1*
10µF
V
OUT
V
IN
LT1086
LT1086 • TA04
+
C2
100µF
+
R1
121
*NEEDED IF DEVICE IS FAR FROM FILTER CAPACITORS
V
OUT
= 1.25V 1 +
R2
R1
(
)
Battery Charger
V
IN
V
OUT
R2
I
F
R
S
R1
LT1086
1.25V
LT1086 • TA06
R2
R1
1 +V
OUT
– 1.25
()
R2
R1
1 + – R
S
I
F
=
()
1
R2
R1
1 + – R
S
=
()
dI
F
dV
OUT
()
IN
V
IN
OUT
TTL
ADJ
1k
1k
10µF
100µF
5V
LT1086
2N3904
LT1086 • TA05
+
121Ω
1%
365Ω
1%
+
5V Regulator with Shutdown