Datasheet

LTC2977
53
2977fa
For more information www.linear.com/LTC2977
MFR_VINEN_OV_FAULT_RESPONSE
This command register determines whether V
OUT
overvoltage faults from a given channel cause the V
IN_EN
pin to be
pulled low.
MFR_VINEN_OV_FAULT_RESPONSE Data Contents
BIT(S) SYMBOL OPERATION
b[7] Mfr_vinen_ov_fault_response_chan7 Response to channel 7 VOUT_OV_FAULT.
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.
b[6] Mfr_vinen_ov_fault_response_chan6 Response to channel 6 VOUT_OV_FAULT.
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.
b[5] Mfr_vinen_ov_fault_response_chan5 Response to channel 5 VOUT_OV_FAULT.
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.
b[4] Mfr_vinen_ov_fault_response_chan4 Response to channel 4 VOUT_OV_FAULT.
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.
b[3] Mfr_vinen_ov_fault_response_chan3 Response to channel 3 VOUT_OV_FAULT.
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.
b[2] Mfr_vinen_ov_fault_response_chan2 Response to channel 2 VOUT_OV_FAULT.
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.
b[1] Mfr_vinen_ov_fault_response_chan1 Response to channel 1 VOUT_OV_FAULT.
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.
b[0] Mfr_vinen_ov_fault_response_chan0 Response to channel 0 VOUT_OV_FAULT.
1 = Disable (pull low) V
IN_EN
via fast pull-down.
0 = Do not disable V
IN_EN
.
PMBus