Datasheet

LTM8061
11
8061fa
For more information www.linear.com/LTM8601
8061 F01
BATTERY VOLTAGE
BATTERY CHARGE
CURRENT
RUN
CHRG
FAULT
MAXIMUM CHARGE CURRENT
PRECONDITION CURRENT
C/10
0 AMPS
FLOAT VOLTAGE
RECHARGE THRESHOLD
PRECONDITION THRESHOLD
1
0
1
0
0
1
applicaTions inForMaTion
8061 F02
BATTERY VOLTAGE
BATTERY CHARGE
CURRENT
RUN
CHRG
FAULT
MAXIMUM CHARGE CURRENT
PRECONDITION CURRENT
C/10 CURRENT
AUTOMATIC
RESTART
FLOAT VOLTAGE
RECHARGE THRESHOLD
PRECONDITION THRESHOLD
1
0
1
0
0
< t
EOC
/8
t
EOC
1
Figure 1. Typical C/10 Terminated Charge Cycle (TMR Grounded, Time Not to Scale)
Figure 2. Typical EOC (Timer-Based) Terminated Charge Cycle (Capacitor Connected to TMR, Time Not to Scale)