Datasheet
29
21454314fa
LTC2145-14/
LTC2144-14/LTC2143-14
APPLICATIONS INFORMATION
Table 3. Serial Programming Mode Register Map (PAR/SER = GND)
REGISTER A0: RESET REGISTER (ADDRESS 00h)
D7 D6 D5 D4 D3 D2 D1 D0
RESETXXXXXXX
Bit 7 RESET Software Reset Bit
0 = Not Used
1 = Software Reset. All Mode Control Registers Are Reset to 00h. The ADC is momentarily placed in SLEEP mode. This bit is
automatically set back to zero at the end of the SPI write command. The reset register is write only. Data read back from the reset
register will be random.
Bits 6-0 Unused, Don’t Care Bits.
REGISTER A1: POWER-DOWN REGISTER (ADDRESS 01h)
D7 D6 D5 D4 D3 D2 D1 D0
XXXXXXPWROFF1 PWROFF0
Bits 7-2 Unused, Don’t Care Bits.
Bits 1-0 PWROFF1:PWROFF0 Power Down Control Bits
00 = Normal Operation
01 = Channel 1 in Normal Operation, Channel 2 in Nap Mode
10 = Channel 1 and Channel 2 in Nap Mode
11 = Sleep Mode
REGISTER A2: TIMING REGISTER (ADDRESS 02h)
D7 D6 D5 D4 D3 D2 D1 D0
XXXXCLKINV CLKPHASE1 CLKPHASE0 DCS
Bits 7-4 Unused, Don’t Care Bits.
Bit 3 CLKINV Output Clock Invert Bit
0 = Normal CLKOUT Polarity (As Shown in the Timing Diagrams)
1 = Inverted CLKOUT Polarity
Bits 2-1 CLKPHASE1:CLKPHASE0 Output Clock Phase Delay Bits
00 = No CLKOUT Delay (As Shown in the Timing Diagrams)
01 = CLKOUT
+
/CLKOUT
–
Delayed by 45° (Clock Period • 1/8)
10 = CLKOUT
+
/CLKOUT
–
Delayed by 90° (Clock Period • 1/4)
11 = CLKOUT
+
/CLKOUT
–
Delayed by 135° (Clock Period • 3/8)
Note: If the CLKOUT Phase Delay Feature Is Used, the Clock Duty Cycle Stabilizer Must Also Be Turned On
Bit 0 DCS Clock Duty Cycle Stabilizer Bit
0 = Clock Duty Cycle Stabilizer Off
1 = Clock Duty Cycle Stabilizer On