Total Harmonic Distortion (THD)
Total harmonic distortion (THD) is the ratio of the
RMS sum of all harmonics of the input signal to the
fundamental itself. The out-of-band harmonics alias into
the frequency band between DC and half the sampling
frequency (
fSMPL
/2). THD is expressed as:
THD
V V V V
V
N
=
+ + +
20
2
2
3
2
4
2 2
1
log
...
where V
1
is the RMS amplitude of the fundamental
frequency and V
2
through V
N
are the amplitudes of the
second through Nth harmonics.
Internal Reference
The LTC2309 has an on-chip, temperature compen-
sated bandgap reference that is factory trimmed to
2.5V (Refer to Figure 6a). It is internally connected to a
reference amplifier and is available at V
REF
. V
REF
should
be bypassed to GND with a 2.2μF ceramic capacitor to
minimize noise. An 8k resistor is in series with the output
so that it can be easily overdriven by an external refer-
ence if more accuracy and/or lower drift are required,
as shown in Figure 6b. The reference amplifier gains
the V
REF
voltage by 1.638 to 4.096V at REFCOMP. To
compensate the reference amplifier, bypass REFCOMP
with a 10μF ceramic capacitor in parallel with a 0.1μF
ceramic capacitor for best noise performance. The
internal reference buffer can also be overdriven from
1V to V
DD
, as shown in Figure 6c. To do so, V
REF
must
be grounded to disable the reference buffer.
AppLICAtIOns InFORMAtIOn
Figure 5. 1kHz Sine Wave 8192 Point FFT Plot
R2
R3
REFERENCE
AMP
0.1µF
10µF
2.2µF
REFCOMP
GND
V
REF
R1
8k
2.5V
4.096V
LTC2309
2309 F06a
BANDGAP
REFERENCE
Figure 6a. LTC2309 Reference Circuit
0.1µF
10µF
2309 F06b
LT1790A-2.5
V
OUT
V
IN
5V
V
REF
LTC2309
GND
REFCOMP
2.2µF
0.1µF
Figure 6b. Using the LT
®
1790A-2.5 as an External Reference
FREQUENCY (kHz)
0
–140
MAGNITUDE (dB)
–120
–100
–80
0
–40
1
3
4 7
2309 G03
–20
–60
2
5
6
SNR = 73.4dB
SINAD = 73.3dB
THD = –88dB
Figure 6c. Overdriving REFCOMP Using the LT1790A-4.096
0.1µF
0.1µF
10µF
2309 F06c
LT1790A-4.096
V
OUT
V
IN
5V
V
REF
LTC2309
GND
REFCOMP