LFC 3000 Users Manual Series A June 2002 Form 403082 Section - F60 Page -2
LFC 3000 Users Manual Series A Table of Contents Safety Instructions..........................................................................2 Description......................................................................................3 Memory Protected..........................................................................3 Technical Data................................................................................4 User Menu....................................................................
LFC 3000 Users Manual Series A DESCRIPTION The LFC 3000 is a modular fluid management/security system for service workshops. It provides the shop supervisor with a host of services required for precise management of an inventory of products such as oil and antifreeze. The LFC 3000 maintains the inventory by controlling access to hoses, precise metering of the products, and accurate accounting.
LFC 3000 Users Manual Series A TECHNICAL DATA Enter Hose _0 Network specifications The LFC 3000 operates with a CAN Bus network that uses two wires and a shield. System specifications Keypads on a system I/O modules on a system Solenoid valves on a system Meters with single channel pulse transmitters Fluids on a system Number of operators Transaction log Simultaneous dispenses Printers per system 64 max. 8 max. 64 max. 64 max. 8 max. 99 max. 1900 max. 64 max. 64 max.
LFC 3000 Users Manual Series A Transaction By user By hose By product All transactions Exit reports are available: Report by user (Enter the users number) Report by hose (Enter the hoses number) Report by product (Enter the products number) sor PIN Number has been forgotten, it will be necessary to reset the system. See Instruction Manual under Troubleshooting, Lost Supervisor PIN. ENTER Supervisor pin 9999 All Reports Supervisor Menu Delivery Rep.
LFC 3000 Users Manual Series A Supervisor Menu Add New User Up to 99 users can be stored in the system. Any 4 digit PIN numbers can be assigned to an operator. It is recommended that the supervisor keep a list of the PIN numbers in case he needs to remove one of them. Two users cannot have the same PIN Number. ENTER New User Pin **** ENTER New User Name (User name) CUSTOMER MENU The Customer Configure Menu is accessible though all the keypads.
LFC 3000 Users Manual Series A Customer Menu Warn Level Dispense Mode Pre-Select - Free Dispense A minimum stock level must be set for each tank. All fluids dispenses will automatically be deducted from the respective tank stock. When the stock level in the tank reaches the warning level, a warning reordering message will automatically be printed on the report printer. ENTER Use Up / Down arrow key to select the tank Customer Menu Odometer & Reg.
LFC 3000 Users Manual Series A System Cfg PIN 2222 Inactive Timeout 120 In a multi I/O system without PC, this parameter must programmed and must be the same on each I/O. Access to the System Configuration installer level. The factory PIN number is 2222 for the System Menu. Customer Menu Set Language Customer Menu Exit ENTER Use Up / Down key to select the language. LFC 3000 is a multi language system. The default language is British English. To change to American English, you must enter US0011.
LFC 3000 Users Manual Series A Every display is delivered with dip switches on the PC board. See Instruction Manual, Wiring the display. ENTER Select Hose 01 ENTER Select Display 00 ENTER Hose Number 1 will be visualized on display Number 00. System Menu Set Encoder Type LFC 3000 allows the use of single channel and dual channels pulse transmitters. By default, all the systems are programmed to be use with single channel pulse transmitters.
LFC 3000 Users Manual Series A System Menu Set Ticket B Adr. To fulfill all the needs of the garage supervisor, LFC 3000 offers also the flexibility to print a copy of the transaction tickets. All the printers must be connected through the serial port and be Epson emulated. This printer can be the main printer. This instruction must be done on EACH keypad. The factory default setting is ticket B address on keypad 0.
LFC 3000 Users Manual Series A System Menu Hose Calibration This prompt is offering the possibility to correct the delay of the solenoid valve shut-off. When an operator presets a quantity of fluid to be dispensed, the system will automatically close the solenoid valve when the preset quantity has been reached. The LFC 3000 counts the pulses coming from the pulse transmitter.
LFC 3000 Users Manual Series A FLOW CHART Enter PIN Number ____ 9999 Enter PIN user - Enter Good Morning User’s Name Customer Menu ____ 1111 - Enter Good Morning Supervisor System Menu Test Mode Customer Menu Hose System Menu Display Alloc. Customer Menu Warn. Level System Menu Set Encoder Type Customer Menu Stop Level System Menu System Type Supervisor Menu Stock Lev. Rep. Customer Menu Stock Mode System Menu Set Rep. Addr. Supervisor Menu Prod. Delivery Cust.