USER MANUAL LA36 ACTUATOR To learn more about LINAK, please visit: W W W. L I N A K .
Contents Preface ................................................................................................................................................................. 4 Safety instructions .............................................................................................................................................. 5 Declarations of conformity ................................................................................................................................ 6 Misc.
Preface We are delighted that you have chosen a product from LINAK. LINAK systems are high-tech products based on many years of experience in the manufacture and development of actuators, electronic control boxes, controls, and chargers. We are also constantly improving our products to meet customer requirements. This user manual will tell you how to install, use, and maintain your LINAK LA36 actuator. We are sure that the LA36 actuator will give you a problem-free operation.
Safety instructions Please read the following safety information carefully. Ensure that all staff who are to connect, mount, or use the actuator are in possession of the necessary information and that they have access to this user manual. Persons who do not have the necessary experience or knowledge of the product/ products must not use the product/products.
Important information Information about the actuators is described under the following two headings: Warning! Failing to follow these instructions can cause accidents resulting in serious personal injury. Failing to follow these instructions can result in the actuator suffering damage or being ruined.
Misc. on the TECHLINE® actuator system Warranty There is a 12 months’ warranty on the TECHLINE products against manufacturing faults calculated from the production date of the individual products (see label). LINAK’s warranty is only valid in so far as the equipment has been used and maintained correctly and has not been tampered with. Furthermore, the actuator must not be exposed to violent treatment. In the event of this, the warranty will be ineffective/ invalid.
Specifications Motor: Permanent magnet motor 12, 24, or 36V * Motor protection: Automatic protection resets thermal overload (Option) Cable: Motor: 2 x 14 AWG PVC cable Control: 6 x 20 AWG PVC cable ** Gear ratio: 6 different gear ratios available in steel (500 N, 1,700 N/2,600 N, 4,500 N, and 6,800/10,000 N) Slip clutch: Mechanical - overload protection through an integrated slip clutch is optional adjusted to 1.2-1.4 times max. load Brake: Integrated brake ensures a high self-locking ability.
Mounting guidelines X LINAK® linear actuators are quickly and easily mounted by slipping pins through the holes on each end of the units and into brackets on the machine frame and the load. The mounting pins must be parallel to each other as shown in Figure 1. Pins, which are not parallel to each other, may cause the actuator to bend and be damaged. X Figure 1 The load should act along the stroke axis of the actuator since off centre loads may cause bending and lead to premature failure. See Figure 2.
Application hints The actuator is weatherproof for use in outdoor applications. The actuator can be washed down with a high-pressure washer, but it should not be used under water. Optionally the actuator is overload protected with a slip clutch. The clutch will slip when the load exceeds approx. 1.2 - 1.4 times the actuator’s rating. The duty cycle at max. load is 20% on time. This means if the actuator runs continuously for 20 seconds it must remain off for 80 seconds before operating again. NB.
Electrical installation Be aware of BUS actuator - please see the separate installation guide. Motor connection Wiring: The actuator direction (forward, reverse) is controlled with a doublethrow switch with the centre postion “off”. + Motor Actuation To extend the actuator, connect brown to positive and blue to negative. To retract the actuator, connect blue to positive and brown to negative.
Connections diagram: For 36xxxxx2Pxxxxxx and 36xxxxx20xxxxxx: Power cable P C B : 0 0 L A 3 6 W P E -C -X + B ro w n M o to r P o w e r + /- ( o u t / in ) 1 2 V /2 4 V /3 6 V - B lu e 2 4 V S ig n a ls O U T 1 0 R e d S u p p ly + 1 2 v to 3 6 V 8 0 m A E n d O U T E n d IN 5 K 6 E n d IN 1 0 Y e llo w 1 0 G re e n E n d O U T W h ite + 1 0 V e x ita t io n V io le t 0 - 1 0 V O u t 5 K 6 0 0 1 K 1 0 K 0 B la c k G N D Signal cable Connections diagram: For 36xxxxx2Hxxxxxx
Connections diagram: For 36xxxxx3xxxxBxx + 36xxxxx40xxxBxx: Power cable P C B : 0 0 C S 3 6 -X -0 + B ro w n E N D E N D M o to r P o w e r 2 4 V /3 6 V - B lu e 2 4 V S ig n a ls O U T 1 0 R e d S u p p ly + 1 2 v to 2 4 V O U T 8 0 m A B A 1 0 Y e llo w H a ll A 1 0 G re e n 1 K W h ite O U T 1 K V io le t IN B la c k G N D IN (E n d IN ) 5 K 6 H a ll B (E n d O U T ) 5 K 6 7 V 4 V 7 V 4 V 5 K 6 5 K 6 Connections diagram: For 36xxxxx1/2Bxxxx Signal cable Power ca
Connection of the LA36 with the CS16 MAX MIN P HB40 serie CS16-4-24 1 2 3 4 5 6 7 8 9 10 11 12 R GR O R = RED . O = ORANGE .
Mounting of cables TORX 25IP • Unscrew the cover and remove the two blind plugs • Plug in the power cable and/or the signal cable • Slide the cover onto the actuator The torque of the cover screw is +/- 0.3 Nm Note: When changing the cables on a LINAK actuator, it is important that this is done carefully, in order to protect the plugs and pins. Please be sure that the plug is in the right location and fully pressed in before the cable lid is mounted.
DRAWING APPENDIX TECHLINE® LA36: LA36 ST ROKE <= 3 0 0 = 200 + STR O K E ST ROKE => 3 00 = 250 + STR O K E 02= Turned 90˚ 01= Standard 17
Built-in dimensions Piston rod Back fixture “0” / from the surface “1” / to the centre of the hole “2” / to the centre of the hole “3” / from the surface Stroke <= 300 Stroke > 300 Stroke <= 300 Stroke > 300 Stroke <= 300 Stroke > 300 Stroke <= 300 Stroke > 300 “0” / from the surface 189 239 194 244 194 244 181 231 “1” and “2” / to the centre of the hole 195 245 200 250 200 250 187 237 “3” and “4” / to the centre of the hole 195 245 200 250 200 250 187 237 “5” / from
Main groups of disposal Product Metal scrap Cable scrap Electronic scrap Plastic recycling or combustion X X X X LA36 LINAK’s products may be disposed of, possibly by dividing them into different waste groups for recycling or combustion. We recommend that our product is disassembled as much as possible at the disposal and that you try to recycle it.
FACTORIES DENMARK LINAK A/S . Group Headquarters Guderup Phone: +45 73 15 15 15 . Fax: +45 74 45 80 48 Fax (Sales): +45 73 15 16 13 E-mail: info@linak.com . www.linak.com NORWAY LINAK Norge AS Phone: +47 32 82 90 90 . Fax: +47 32 82 90 98 E-mail: info@linak.no . www.linak.no POLAND LINAK Polska Phone: +48 (22) 500 28 74 . Fax: +48 (22) 500 28 75 E-mail: dkreh@linak.dk . www.linak.pl SLOVAKIA LINAK Slovakia s.r.o. Phone: +421 517563 414 . Fax: +421 517563 410 E-mail: jp@linak.sk . www.linak.