Specifications

Page 101 of 152
The recommended screw type is self-tapping BN84229 50 x 12.
A grounding cable (article no.: 1009W7004) will be supplied together with the ACT and must be connected to the OpenBus
TM
system and the other
end to the bed frame to decouple electrical fields.
...to be continued
Ferrite core :
If upward cable exit is used, a ferrite core needs to be added as close as possible to the ACT.
Ferrite core specification:
At the mentioned frequencies, the impedance must be as stated in the table:
Frequency (MHz) 10 25 100 250
Impedance (Ω) 95 156 260 270
Ferrite core graphic characteristics:
Impedance, reactance, resistance vs. frequency