Datasheet
Environmental test - Climatic
Test Specifi cation Comment TRD number
Degrees of protection EN60529 –
IP6x
IP6X - Dust: Dust-tight, No ingress of dust.
Actuator is not activated.
TRD2351
EN60529 –
IPx6
IPX6 - Water: Ingress of water in quantities causing
harmful effects is not allowed.
Duration: 100 litres pr. minute in 3 minutes.
Actuator is not activated.
TRD2249
EN60529 –
IPx6 - dynamic
IPX6 - Connected actuator:
Actuator is driving out and in for 3 min. 100 (l/min) jet of
water is placed at the wiper ring for 3 (min).
TRD2349
DIN40050 –
IP69K
High pressure cleaner:
Water temperature: +80°C
Water pressure: 80 bar Spray angle: 45°
Spray distance: 100 mm
Duration: From any direction 10 seconds of spraying
followed by 10 seconds rest.
Actuator is not activated.
Ingress of water in quantities causing harmful effects is
not allowed.
TRD2350
Salt mist. EN60068-2-52
(Kb)
Dynamic salt spray test
Salt solution: 5% sodium chloride (NaCl)
4 spraying periods, each of 2 hours.
Humidity storage 20 days after each.
Actuator is power up connected during the test.
Exposure time: 10.000 cycles
TRD2570
Test Specifi cation Comment TRD number
Low Temperature
Soak
Unit powered and operating for 96Hrs @ -40°C TRD2232
High Temperature
Soak
Unit powered and operating for 96Hrs @ 105°C TRD2233
Mechanical Shock
(Handling) - Drop Test
BS2011
Part 2.1 Eb.
400mm drop onto Hardwood bench minimum 40 mm
thick. Onto all practical edges and faces
TRD2243
Mechanical Shock
(Operational)
100 off 400m/sec2 6 ms shock pulses - in 3 axes TRD2229 PART 1
Vibration (Random) 24 hours in each ax. Breakpoint Freq.
10Hz @ 0.005 g2/Hz,
150Hz @ 0.060 g2/Hz,
220Hz @ 0.080 g2/Hz
350Hz @ 0.040 g2/Hz
TRD2229 PART 2
TRD 3802
Vibration
(Resonant Search)
10 Hz - 2 KHz @ 4G, Rate = 1octave/min TRD2229 PART 3
TRD 3802
Bump 40G in 6 mS x 100 in each direction pr. axis TRD 3802
EMC Test See TRD TRD 4661
Electrical Tests See TRD TRD 3209
TRD 4356
Environmental test - Mechanical
Environmental test - Electrical