Important Safety Instructions
Please read the supplied safety instruction document before using the product and keep it
available for future reference.
Introduction
The VINX ‘AP-series’ is the second generation of the VINX family. These products extend the
features of the rst generation with the following functions: VGA input port, Analog audio (de)
embedding and transmission over SFP modules. The devices can also be powered over Ethernet
(PoE). The built-in audio de-embedding feature allows the HDMI audio to be transmitted as a
2-channel Dante
®
or AES67 source from the DNT model via the extra RJ45 connector.
Compatible Devices
The VINX AP-series devices are compatible with the VINX-120-HDMI-ENC and
VINX-110-HDMI-DEC (basic VINX) devices. Please note that certain features are not available
when mixing VINX-AP and basic VINX devices:
* VGA is available in VINX-210AP-HDMI-ENC model only.
** In VINX-120AP-HDMI-ENC-DNT model only.
Dante
®
is a registered trademark of Audinate Pty Ltd.
Box Contents
Rear View of VINX-120AP-HDMI-ENC
Rear View of VINX-210AP-HDMI-ENC
Rear View of VINX-110AP-HDMI-DEC
Front View of VINX-120AP-HDMI-ENC and VINX-120AP-HDMI-ENC-DNT *
Front View of VINX-210AP-HDMI-ENC
Front View of VINX-110AP-HDMI-DEC
Status LEDs
1
Status LEDs See the attached list.
2
RS-232 Port D-SUB9 connector for transparent serial communication
(point-to-point or point-to-multi point).
3
IR Output Port IR output signal connector (for 3.5 mm Jack, 2-pole, TS plug).
4
DIP Switch Linking Encoder and Decoder devices (HW setting).
5
Audio Select
button
Press the button to toggle between the following modes:
Auto HDMI Analog audio
Auto: the Analog audio input port is selected when a plug is
connected.
6
Compression
Mode Button
Short press: switching between the Video and Graphics
modes.
Long press (more than 10 seconds): reset to factory default
settings.**
7
HDMI Output For a local sink device (mirrored from the A/V output).
1
Reset Button Reboots the device.
2
AV Input Ports RJ45 connector and slot for an SFP module. One at a time
is available for receiving an A/V signal. The device can be
powered over the RJ45 connector (PoE-compatible).
3
HDMI Input Port Video port for DVI or HDMI signal.
4
USB Port B-Type connector for USB pass-through application (e.g. for
connecting the Encoder to a computer).
5
Audio Input Port 3.5 mm jack connector for unbalanced analog audio signal.
6
Audio Output
Port (Encoders)
Presenting the microphone signal coming from the Mic in input
port of the connected Encoder. This feature is available only in
Unicast mode and if Analog audio is selected to be embedded
into the HDMI signal in the Encoder.
7
DC 12V Input 12V DC input for local power supply.
12V DC Power Adaptor,
interchangeable plugs
Encoder/decoder device
Fixing screw for mounting
(M3x4), 2 pcs.
Safety and Warranty info,
Quick Start Guide
Safety and
Warranty
Info
Quick
Start
Guide
1 2 3 74 5 6
1 2 3 4 8 6
1 2 9 e4 q w
1 5 67
2 3 4
1 567
2 3 4 8
1 q e7
2 9
Rear View of VINX-120AP-HDMI-ENC-DNT
1
w
5 67
2 3 4
POWER
on The device is powered.
blinking The device is booting.
off No power source is connected to the device.
VIDEO
on The unit is connected to a network and video streaming is in progress.
blinking The unit is connected to a network, but no video streaming is in progress.
off The device is not connected to a network.
POWER and VIDEO LEDs together
blinking There is a Video Stream ID clash in the network.
USB connection shall be acquired in the Decoder in Multicast mode. In Unicast mode, the
USB connection is established automatically.
* The connectors and labels are shifted left by 11 mm in case of VINX-120AP-HDMI-ENC-DNT.
** Please see the Calling Factory Default Settings section for details.
The microphone input port applies a xed bias to feed the connected electret
(condenser) microphone. Thus, it is not suitable for dynamic microphones that do not
contain isolation or an impedance matching transformer. (Danger of damage to the
microphone.)
Mounting the Device (with optionally available accessories)
The examples demonstrate the applications of the UD Kit double and Rack Shelf accessories:
For xing the device to a Rack shelf, use the screws supplied with the extender.
Longer screws may touch internal parts and harm the device.
8
AV Select
Button
Press the button to toggle between the following modes:
Auto
HDMI+Embedded audio
HDMI+Analog audio
VGA+Analog audio
Auto mode: the rst connected source shall remain active as
long as a signal is present on the respective input. If sync is
lost for at least 3 seconds, it will be switched over to the other
source. No automatic switch back to the original input takes
place when the signal is restored.
9
IR Input Port IR signal input connector (for 3.5 mm Jack, 3-pole, TRS plug).
q
USB Connect
Button
Short press: acquire USB connection (this is required only in
Multicast mode).
Long press (more than 10 seconds): reset to factory default
settings.**
w
Audio Set
Button
Short press: the analog audio output volume is increased by
10%.
Long press (more than 5 seconds): the analog audio output
volume is set to 0%.
e
USB Ports USB 1.1 and 2.0 compatible A-type ports for transmitting USB
HID and mass storage devices.
8
VGA Input Port Video port for analog VGA signal on VINX-210AP-HDMI-ENC.
9
HDMI Output HDMI output to a sink device on VINX-110AP-HDMI-DEC
device.
q
Microphone
Input Port
Mono input port for microphones including 20 dB gain in the
signal path. The signal can be routed back to the Audio output
port of the connected Encoder in Unicast mode.
w
Dante
®
Audio
Output
RJ45 connector for de-embedding the HDMI audio, which can
be transmitted as a 2-channel Dante
®
or AES67 source.
e
Audio Output
Port (Decoder)
Presenting the audio signal coming from the connected
Encoder (it can be enabled/disabled).
Basic series AP series
Video input port HDMI
HDMI, VGA
*
Analog audio (de)embedding
Return audio (mono) - in unicast mode
Dante
®
or AES67 audio de-embedding
**
Network interface RJ45 RJ45, SFP
Powering modes adapter adapter, PoE
Calling Factory Default Settings
Until rmware version v3.3.0, factory default settings can be recalled by pressing the
Compression Mode button (in case of VINX-120AP-HDMI-ENC, VINX-120AP-HDMI-ENC-
DNT and VINX-210AP-HDMI-ENC models) or the USB Connect button (in case of VINX-
110AP-HDMI-ENC model) for more than 10 seconds. From that version on, factory defaults
may only be called this way for 90 seconds after booting up, following that they can only be
called via software control (LDC and LW3).