Guide
-4
Firmware file has invalid header
-5
Flash failed to write
-6
Firmware is for a different hardware
version or firmware version is too
low
-7
Firmware is for a different product
Read
Write
Persists
uint32
130
bytes
-
17. Commit firmware
The second part of uploading firmware to the LW24/C is to commit the staged data. Once the firmware data has been
fully uploaded using the16. Stage Firmwarecommand, then this command can be written to (with 0 bytes).
When reading this command, or analysing its response after writing, the packet will contain anint32error code:
Value
Description
-1
Firmware integrity check failed
1
Firmware integrity check passed and
firmware committed
Once the firmware is committed, a reboot is required to engage the new firmware. This can be done by cycling power
to the LW24 or by sending the14. Resetcommand.
After the unit has rebooted the firmware version should be checked to ensure the new firmware is installed.
Read
Write
Persists
uint32
0 bytes
-
27. Distance output
This command configures the data output when using the 44. Distance data command. Each bit toggles the output of
specific data.
Bit
Output
0
First return raw
LW24/C/RS microLiDAR™ sensor - Product guide | Version 0 | 03 March 2022 Page 30 of 38