Guide
Mechanical safety
● Ensure that there is adequate airflow permitted for the sensor.
● The mechanical dimensions for mounting the LW24/C are provided in the hardware overview.
Laser radiation information
Specification
Value/AEL
Notes
Eye safety classification
Class 1M
Laser wavelength
905 nm
Pulse width
16 ns
Pulse frequency
20 kHz
Average power
< 2.5 mW
NOHD
15 m
Distance beyond which binoculars
may be used safely.
Approximate values only. Please contact LightWare LLC if further information is required.
Service & maintenance
The LW24/C is not field serviceable. For any repairs, the equipment should be completely isolated, removed then
packaged carefully. Please visit LightWare LLC’srefund policyfor Return Merchandise Authorization (RMA) details, or
contactsupport@lightwarelidar.com
Cleaning
Use a dry and clean microfiber cloth to gently wipe across the lenses of the sensor, taking care not to scratch the
surface of the lenses.
LW24/C/RS microLiDAR™ sensor - Product guide | Version 0 | 03 March 2022 Page 19 of 38