User's Manual

7
Power
24v/2.5a
InputOutput
Audio
analog input
Topcat audio link
Program
Fire
Mute
Page
First
Contact
Closure
Topcat Side Panel Connections
OVERVIEW
1 6 752 4
3
1. AUX POWER INPUT CONNECTOR (optional): For use during
installations where AC power is not available in the ceiling.
Accepts 24VDC, 2.5A connector from an external power supply.
2. CONTACT CLOSURE: Internal relay contact closure to provide
signal to notify external system based on user input.
3. RELAY INPUT: Senses external relay closure to mute Topcat
audio when a signal from a fire alarm, IP paging system or
other device is detected.
4. PAGEFIRST INPUT: Connect the input from optional
PageFirst sensor when interfacing with the building’s paging
system. Use the ADJ control inside the speaker cavity to adjust
the sensitivity if needed.
5. TOPCAT AUDIO LINK: Digital Audio Input and Audio Output to
connect one Topcat to another.
6. AUDIO INPUT: This connection accepts an audio signal from
other technology so all multimedia can be distributed evenly
throughout the classroom
7. PROGRAMING CONNECTION: For factory use only.