TL - 5024 MEMORY LIGHTING CONSOLE OWNERS MANUAL Version 0.93 07/20/2012 www.lightronics.com Lightronics Inc.
Page 2 of 13 TL-5024 LIGHTING MEMORY CONSOLE OWNERS MANUAL Version 0.93 07/20/2012 SPECIFICATIONS INSTALLATION Total channels The TL-5024 control console should be kept away from moisture and direct sources of heat.
Page 3 of 13 TL-5024 LIGHTING MEMORY CONSOLE OWNERS MANUAL Version 0.93 07/20/2012 CONTROLS AND INDICATORS X Faders: Y Faders: Cross Faders: Bump Buttons: TAP Button: TAP Indicator: AUDIO SENSE Knob: Y Mode Indicators: Y Mode Button: BLACKOUT Button: BLACKOUT Indicator: Cue Master: Chase Master: Grand Master: House Master: Record Button: Record Indicator: Bump Mode Button: Bump Mode Indicator: GO Button: ENTER Button: Arrow Buttons: Control individual channel levels for channels 1 – 12.
Page 4 of 13 TL-5024 LIGHTING MEMORY CONSOLE OWNERS MANUAL Version 0.93 SETUP AND PRELIMINARY OPERATION CONSOLE RESET The TL-5024 can be set to factory default conditions by performing an ERASE ALL function which is accessed from the LCD menu. ERASE ALL causes the following actions: 1. The cue list will be set to the default values. 2. Chase step scene assignments will be set to the default scenes. Channel settings will be set OFF. 3.
Page 5 of 13 TL-5024 LIGHTING MEMORY CONSOLE OWNERS MANUAL Version 0.93 07/20/2012 STATUS DISPLAY The diagram below shows what information is given on the status display during normal operation. When the menu system is in use then other information will be shown.
Page 6 of 13 TL-5024 LIGHTING MEMORY CONSOLE Version 0.93 OWNERS MANUAL You can assign a dimmer channel to console channel 00. If you do this, then that dimmer channel will not respond to the console. You can also assign a dimmer channel to console channel 99. If you do this, then the dimmer channel will be controlled by the HOUSE MASTER fader. Multiple dimmer channels can be assigned to the house master. You can perform three other operations from the PATCH menus. 1.
Page 7 of 13 TL-5024 LIGHTING MEMORY CONSOLE OWNERS MANUAL Version 0.93 The chase which is to be programmed is shown in the upper left (C01 meaning chase 01). The step number within the chase is shown in the upper right (S01 meaning step 01). The item on the bottom row (EDIT) will access a submenu enabling you to edit that chase/step number. 2. Push the TAP button 3 or more times at the same rate that you want the chase to run. Use the and buttons to select one of the choices.
Page 8 of 13 TL-5024 LIGHTING MEMORY CONSOLE OWNERS MANUAL Version 0.93 The display indicates your entry as the next cue to be activated. When you push GO – this cue will fade in. DEFAULT CUE LIST The TL-5024 is provided with a factory default cue list. This is the condition which will be set if the ERASE ALL or ERASE CUEING function is invoked from the ERASE menu. The settings for the default cue list are as follows: Cues 1 - 12 are set to scenes 1 - 12 in scene bank 1.
Page 9 of 13 TL-5024 LIGHTING MEMORY CONSOLE OWNERS MANUAL Version 0.93 5. ERASE ALL: Performs all 4 of the erase functions described above. USING ERASE FUNCTIONS 1. Push ENTER ENTER . The display will show the ERASE CUEING menu. 2. Push ENTER to erase the cues. or Push move to the next erase function. to Once in the erase menus you can use the and buttons to cycle through all of the erase function choices.
Page 10 of 13 TL-5024 LIGHTING MEMORY CONSOLE Version 0.93 OWNERS MANUAL 07/20/2012 UNLINKING ALL RECEIVERS EXTERNAL POWER SUPPLY INFORMATION Hold the link control button down for about 5 seconds. The TL-5024 may be powered by an external supply with the following specifications: The indicator LED will go to a flash state for about 10 seconds then return to ON. The link indicator on the receiver unit(s) will go OFF. Link release for a single receiver unit can only be performed at the receiver unit.
Page 11 of 13 TL-5024 LIGHTING MEMORY CONSOLE OWNERS MANUAL Version 0.93 07/20/2012 USING THE MENUS The TL-5024 uses a menu system to control four functions. They are the CUEING, CHASER, PATCH, and ERASE functions. Some menus have more than one display screen. The menus are accessed by pushing the ENTER button. The diagram below shows the overall layout of the menus. The arrow characters shown in some of the displays tell which button to push to change a value or advance to another item.
Page 12 of 13 TL-5024 LIGHTING MEMORY CONSOLE OWNERS MANUAL Version 0.93 07/20/2012 DEFAULT CHASE SCENE ASSIGNMENTS The following assignments will be made when ERASE CHASER or ERASE ALL is run.
WARRANTY All Lightronics products are warranted for a period of TWO/FIVE YEARS from the date of purchase against defects in materials and workmanship. A) If service is required, you may be asked to provide proof of purchase from an authorized Lightronics dealer. B) The FIVE YEAR WARRANTY is only valid if the warranty card is returned to Lightronics accompanied with a copy of the original receipt of purchase within 30 DAYS of the purchase date, if not then the TWO YEAR WARRANTY applies.
www.lightronics.com Lightronics Inc.