User Guide
Calculite
®
HID Downlight C7E170VM
Page 2 of 2 7" Aperture, ED17 (Open Rated), Ceramic Metal Halide, Medium Beam
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504
Job Information Type:
2,250
4,500
3,000
1,500
4,500
6,000
2,250
4,500
6,750
9,000
30°
60°
30°
60°
30°
60°
70W ED17- PHILIPS CMH OPEN RATED LAMP-3K, LUMEN RATING = 5700 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH REFLECTOR TRIM
ANGLE MEAN CP LUMENS
0 4470
5 4140 392
10 3669
15 3195 902
20 2664
25 2189 999
30 1590
35 1037 677
40 648
45 334 262
50 38
55 7 12
60 1
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 2292 40.22 70.66
0-40 2969 52.1 91.53
0-60 3243 56.91 99.99
0-90 3244 56.92 100
40-90 274 4.82 8.47
60-90 0 0.01 0.01
90-180 0 0 0
0-180 3244 56.92 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 16615
55 435
65 28
75 0
85 0
** EFFICIENCY = 56.9% ** CERTIFIED TEST REPORT NO. 2394FR, DATE: FEB 10, 2004
SC = .7 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .68 .68 .68 .68 .66 .66 .63 .63 .61 .61 .57
1 .65 .64 .63 .61 .63 .60 .60 .59 .58 .57 .54
2 .63 .60 .58 .57 .59 .56 .57 .55 .56 .54 .52
3 .60 .57 .55 .53 .56 .53 .55 .52 .54 .51 .49
4 .58 .54 .52 .50 .54 .49 .52 .49 .51 .48 .47
5 .55 .51 .49 .47 .51 .46 .50 .46 .49 .46 .44
6 .53 .49 .46 .44 .48 .44 .48 .44 .47 .43 .42
7 .51 .46 .43 .41 .46 .41 .45 .41 .45 .41 .40
8 .49 .44 .41 .39 .43 .39 .43 .39 .42 .39 .38
9 .46 .42 .39 .37 .41 .37 .41 .36 .40 .36 .35
10 .44 .39 .37 .34 .39 .34 .39 .34 .38 .34 .34
LUMINAIRE INPUT WATTS = 78
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
100W ED17- PHILIPS CMH OPEN RATED LAMP-3K, LUMEN RATING = 8500 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH REFLECTOR TRIM
ANGLE MEAN CP LUMENS
0 6144
5 5968 562
10 5465
15 4868 1372
20 4164
25 3520 1602
30 2639
35 1739 1130
40 1080
45 615 485
50 197
55 22 55
60 5
65 0 1
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 3536 41.6 67.9
0-40 4666 54.9 89.6
0-60 5206 61.25 99.98
0-90 5207 61.27 100
40-90 541 6.37 10.4
60-90 1 0.01 0.02
90-180 0 0 0
0-180 5207 61.27 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 30624
55 1340
65 0
75 0
85 0
** EFFICIENCY = 61.3% ** CERTIFIED TEST REPORT NO. 2396FR, DATE: FEB 10, 2004
SC = .8 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .73 .73 .73 .73 .71 .71 .68 .68 .65 .65 .61
1 .70 .68 .67 .66 .67 .65 .65 .63 .62 .61 .58
2 .67 .65 .63 .61 .64 .60 .62 .59 .60 .58 .55
3 .64 .61 .58 .56 .60 .56 .59 .55 .57 .54 .53
4 .62 .58 .55 .53 .57 .52 .56 .52 .55 .51 .50
5 .59 .55 .51 .49 .54 .49 .53 .49 .52 .48 .47
6 .57 .52 .49 .46 .51 .46 .50 .46 .50 .46 .45
7 .54 .49 .46 .43 .49 .43 .48 .43 .47 .43 .42
8 .52 .46 .43 .41 .46 .41 .45 .40 .45 .40 .39
9 .49 .44 .40 .38 .43 .38 .43 .38 .42 .38 .37
10 .47 .41 .38 .36 .41 .36 .40 .36 .40 .35 .35
LUMINAIRE INPUT WATTS = 110
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
150W ED17- PHILIPS CMH OPEN RATED LAMP-3K, LUMEN RATING = 11900 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH REFLECTOR TRIM
ANGLE MEAN CP LUMENS
0 9142
5 8732 824
10 7907
15 6927 1952
20 5787
25 4726 2155
30 3385
35 2193 1440
40 1397
45 758 594
50 152
55 24 47
60 9
65 1 3
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 4930 41.44 70.3
0-40 6370 53.54 90.83
0-60 7011 58.92 99.96
0-90 7013 58.94 100
40-90 642 5.4 9.17
60-90 2 0.02 0.04
90-180 0 0 0
0-180 7013 58.94 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 37764
55 1454
65 66
75 0
85 0
** EFFICIENCY = 58.9% ** CERTIFIED TEST REPORT NO. 2395FR, DATE: FEB 10, 2004
SC = .8 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .70 .70 .70 .70 .69 .69 .65 .65 .63 .63 .59
1 .67 .66 .65 .64 .65 .63 .62 .61 .60 .59 .56
2 .65 .62 .60 .59 .61 .58 .59 .57 .58 .56 .54
3 .62 .59 .57 .55 .58 .54 .57 .53 .55 .53 .51
4 .60 .56 .53 .51 .55 .51 .54 .50 .53 .50 .48
5 .57 .53 .50 .48 .53 .48 .51 .47 .51 .47 .46
6 .55 .51 .47 .45 .50 .45 .49 .45 .48 .45 .44
7 .52 .48 .45 .43 .47 .42 .47 .42 .46 .42 .41
8 .50 .45 .42 .40 .45 .40 .44 .40 .44 .40 .39
9 .48 .43 .40 .38 .42 .38 .42 .37 .42 .37 .36
10 .46 .41 .38 .35 .40 .35 .40 .35 .39 .35 .34
LUMINAIRE INPUT WATTS = 167
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
1,125
3,375