User Guide

Lighting Systems Baselyte-BSL6
Page 2 of 8 3 Light T5 HO Direct/Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Module Lengths & Mounting Distances
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
Joiner
BSLESW = suspended standard white
End Set
BSLJS = suspended joiner
System Components & Accessories
Run Configuration
Report No: 2101656
Lamps: F54T5
Lumens per Lamp: 4650
Efficiency: 88.2%
Up: 83.2% Down: 16.8%
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE






















CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 2606 2606 2606 2606 2606
175 2591 2596 2604 2612 2615
165 2496 2527 2562 2599 2613
155 2320 2382 2475 2556 2586
145 2066 2170 2342 2513 2566
135 1747 1901 2189 2434 2515
125 1375 1589 1998 2321 2429
115 966 1270 1783 2069 2145
105 528 945 1305 1340 1384
95 126 332 465 418 451
90 7 41 65 76 72
85 22 47 71 77 83
75 71 85 104 112 121
65 142 190 173 163 170
55 302 329 306 252 259
45 494 432 478 436 437
35 687 612 592 613 621
25 865 843 714 675 693
15 1012 1045 987 895 890
5 1101 1109 1128 1136 1142
0 1110 1110 1110 1110 1110
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 87 87 87 77 77 77 57 57 57
1 76 73 70 67 64 62 50 48 46
2 66 61 57 58 54 51 44 41 39
3 58 52 47 51 46 42 39 35 32
4 52 45 40 46 40 36 34 30 28
5 46 39 34 40 35 31 30 27 24
6 41 34 29 36 31 26 27 23 20
7 37 30 26 33 27 23 25 21 18
8 33 27 22 29 24 20 22 18 16
9 30 24 20 27 21 18 20 17 14
10 27 21 17 24 19 16 19 15 12
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
12309
10242.5
2066.5 16.8
83.2
100.0
14.8
73.4
88.2
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 87 87 87 77 77 77 57 57 57
1 76 73 70 67 64 62 50 48 46
2 66 61 57 58 54 51 44 41 39
3 58 52 47 51 46 42 39 35 32
4 52 45 40 46 40 36 34 30 28
5 46 39 34 40 35 31 30 27 24
6 41 34 29 36 31 26 27 23 20
7 37 30 26 33 27 23 25 21 18
8 33 27 22 29 24 20 22 18 16
9 30 24 20 27 21 18 20 17 14
10 27 21 17 24 19 16 19 15 12
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
12309
10242.5
2066.5 16.8
83.2
100.0
14.8
73.4
88.2
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.