User Guide

Lighting Systems Baselyte-BSL5
Page 2 of 8 2 Light T5 HO Direct/Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Module Lengths & Mounting Distances
Joiner
BSLESW = suspended standard white
End Set
BSLJS = suspended joiner
System Components & Accessories
Run Configuration
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.
Report No: 2101640
Lamps: F54T5
Lumens per Lamp: 4650
Efficiency: 82.2%
Up: 79.4% Down: 20.6%
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE






















CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 1598 1598 1598 1598 1598
175 1590 1592 1596 1601 1602
165 1536 1546 1557 1567 1573
155 1434 1449 1474 1493 1505
145 1286 1306 1365 1439 1461
135 1092 1123 1249 1357 1397
125 865 922 1111 1274 1338
115 613 712 988 1191 1254
105 339 524 804 847 904
95 84 222 379 363 427
90 5 34 48 61 59
85 15 33 56 63 68
75 55 54 77 91 99
65 113 131 82 96 103
55 259 254 190 101 99
45 431 338 355 266 254
35 609 510 469 445 447
25 770 726 593 533 548
15 901 915 857 745 730
5 979 981 998 999 1007
0 987 987 987 987 987
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 82 82 82 73 73 73 55 55 55
1 72 69 66 63 61 59 48 46 45
2 63 58 54 56 52 48 42 40 37
3 55 50 45 49 44 41 37 34 32
4 49 43 38 44 38 34 33 30 27
5 44 37 33 39 34 30 30 26 23
6 39 33 28 35 30 26 27 23 20
7 35 29 25 31 26 22 24 21 18
8 32 26 22 28 23 20 22 18 16
9 29 23 19 26 21 18 20 17 14
10 26 21 17 24 19 16 19 15 13
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
7646
6073
1573 20.6
79.4
100.0
16.9
65.3
82.2
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 82 82 82 73 73 73 55 55 55
1 72 69 66 63 61 59 48 46 45
2 63 58 54 56 52 48 42 40 37
3 55 50 45 49 44 41 37 34 32
4 49 43 38 44 38 34 33 30 27
5 44 37 33 39 34 30 30 26 23
6 39 33 28 35 30 26 27 23 20
7 35 29 25 31 26 22 24 21 18
8 32 26 22 28 23 20 22 18 16
9 29 23 19 26 21 18 20 17 14
10 26 21 17 24 19 16 19 15 13
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
7646
6073
1573 20.6
79.4
100.0
16.9
65.3
82.2
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).