User Guide

Lighting Systems Baselyte-BSL3
Page 2 of 8 4 Light T8 Direct/Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Module Lengths & Mounting Distances
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
Joiner
BSLESW = suspended standard white
Dust CoverEnd Set
BSLJS = suspended joiner
BSLDCS = 4’ suspended dust cover
System Components & Accessories
Run Configuration
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.
Report No: 2101582
Lamps: F32T8
Lumens per Lamp: 2950
Efficiency: 82.9%
Up: 81.9% Down: 18.1%
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE






















CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 2401 2401 2401 2401 2401
175 2387 2386 2387 2386 2389
165 2302 2297 2310 2321 2332
155 2143 2141 2197 2251 2279
145 1912 1925 2053 2172 2220
135 1619 1667 1881 1994 2046
125 1275 1380 1606 1697 1755
115 889 1047 1230 1205 1262
105 482 628 698 661 746
95 116 148 205 182 251
90 10 34 51 61 65
85 29 45 67 73 77
75 66 84 133 117 119
65 118 171 226 259 273
55 237 247 329 355 373
45 376 327 402 453 471
35 513 426 436 495 521
25 638 551 521 518 522
15 739 681 634 600 598
5 800 789 768 740 742
0 808 808 808 808 808
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 82 82 82 72 72 72 54 54 54
1 71 68 65 63 60 58 47 45 44
2 62 57 53 55 51 47 41 38 36
3 54 49 44 48 43 39 36 33 30
4 48 42 37 42 37 33 32 28 25
5 42 36 31 38 32 28 28 25 22
6 38 31 27 34 28 24 25 22 19
7 34 28 23 30 25 21 23 19 16
8 31 25 20 27 22 18 21 17 14
9 28 22 18 25 20 16 19 15 13
10 25 20 16 22 18 14 17 14 11
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
9784
8008.5
1775.5 18.1
81.9
100.0
15.0
67.9
82.9
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 82 82 82 72 72 72 54 54 54
1 71 68 65 63 60 58 47 45 44
2 62 57 53 55 51 47 41 38 36
3 54 49 44 48 43 39 36 33 30
4 48 42 37 42 37 33 32 28 25
5 42 36 31 38 32 28 28 25 22
6 38 31 27 34 28 24 25 22 19
7 34 28 23 30 25 21 23 19 16
8 31 25 20 27 22 18 21 17 14
9 28 22 18 25 20 16 19 15 13
10 25 20 16 22 18 14 17 14 11
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
9784
8008.5
1775.5 18.1
81.9
100.0
15.0
67.9
82.9