User Guide
Lighting Systems Baselyte-BSL27
Page 2 of 8 3 Light T5 HO Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW = suspended standard white
End Set
BSLJS = suspended joiner
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Report No: 2101610
Lamps: F54T5
Lumens per Lamp: 4650
Efficiency: 96.8%
Up: 100.0% Down: 0.0%
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 3645 3645 3645 3645 3645
175 3626 3632 3645 3656 3660
165 3496 3530 3602 3658 3678
155 3251 3330 3488 3627 3674
145 2901 3037 3320 3531 3593
135 2447 2675 3068 3337 3405
125 1917 2261 2722 2976 3046
115 1330 1782 2225 2417 2455
105 717 1164 1495 1515 1547
95 161 311 435 294 324
90 6 7 12 8 9
85 0 0 0 0 0
75 0 0 0 0 0
65 0 0 0 0 0
55 0 0 0 0 0
45 0 0 0 0 0
35 0 0 0 0 0
25 0 0 0 0 0
15 0 0 0 0 0
5 0 0 0 0 0
0 0 0 0 0 0
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 92 92 92 78 78 78 53 53 53
1 80 76 73 68 65 63 46 45 43
2 69 64 59 59 55 51 40 38 36
3 61 54 49 52 47 43 36 32 30
4 53 46 41 46 40 36 31 28 25
5 47 40 35 40 35 30 28 24 21
6 42 35 30 36 30 26 25 21 18
7 38 30 26 32 26 22 22 18 16
8 34 27 22 29 23 19 20 16 13
9 30 24 19 26 21 17 18 14 12
10 28 21 17 24 18 15 16 13 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
13503
13503
0 0
100.0
100.0
0
96.8
96.8
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 92 92 92 78 78 78 53 53 53
1 80 76 73 68 65 63 46 45 43
2 69 64 59 59 55 51 40 38 36
3 61 54 49 52 47 43 36 32 30
4 53 46 41 46 40 36 31 28 25
5 47 40 35 40 35 30 28 24 21
6 42 35 30 36 30 26 25 21 18
7 38 30 26 32 26 22 22 18 16
8 34 27 22 29 23 19 20 16 13
9 30 24 19 26 21 17 18 14 12
10 28 21 17 24 18 15 16 13 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
13503
13503
0 0
100.0
100.0
0
96.8
96.8
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.