User Guide
Lighting Systems Baselyte-BSL24
Page 2 of 8 4 Light T8 Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW = suspended standard white
Dust CoverEnd Set
BSLJS = suspended joiner
BSLDCS = 4’ suspended dust cover
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Report No: 2101583
Lamps: F32T8
Lumens per Lamp: 2950
Efficiency: 80.7%
Up: 100.0% Down: 0.0%
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 2893 2893 2893 2893 2893
175 2878 2881 2893 2899 2902
165 2776 2795 2847 2873 2886
155 2584 2627 2731 2800 2829
145 2307 2381 2555 2642 2676
135 1953 2074 2285 2353 2384
125 1536 1703 1907 1922 1965
115 1074 1284 1417 1356 1386
105 591 741 792 717 756
95 138 141 200 149 185
90 3 3 10 3 7
85 0 0 0 0 0
75 0 0 0 0 0
65 0 0 0 0 0
55 0 0 0 0 0
45 0 0 0 0 0
35 0 0 0 0 0
25 0 0 0 0 0
15 0 0 0 0 0
5 0 0 0 0 0
0 0 0 0 0 0
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 76 76 76 65 65 65 44 44 44
1 66 63 61 57 54 52 39 37 36
2 58 53 49 49 46 43 34 31 30
3 51 45 41 43 39 35 30 27 25
4 44 39 34 38 33 30 26 23 21
5 39 33 29 34 29 25 23 20 18
6 35 29 25 30 25 21 20 17 15
7 31 25 21 27 22 18 18 15 13
8 28 22 18 24 19 16 16 13 11
9 25 20 16 22 17 14 15 12 10
10 23 18 14 20 15 12 13 11 8
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
9517
9517
0 0
100.0
100.0
0
80.7
80.7
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 76 76 76 65 65 65 44 44 44
1 66 63 61 57 54 52 39 37 36
2 58 53 49 49 46 43 34 31 30
3 51 45 41 43 39 35 30 27 25
4 44 39 34 38 33 30 26 23 21
5 39 33 29 34 29 25 23 20 18
6 35 29 25 30 25 21 20 17 15
7 31 25 21 27 22 18 18 15 13
8 28 22 18 24 19 16 16 13 11
9 25 20 16 22 17 14 15 12 10
10 23 18 14 20 15 12 13 11 8
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
9517
9517
0 0
100.0
100.0
0
80.7
80.7
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.