User Guide
Lightolier is a Philips group brand
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • E0708
Specification Decorative Pendalyte
™
40471U
Page 4 of 4 9" Pendant
1
2
3
4
5
6
7
8
9
10
Coefficients Of Utilization 32W Triple Tube CFL
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50 30 10 0
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
.35 .34 .33 .34 .33 .32 .33 .32 .31 .32 .31 .30 .31 .30 .30 .29
.32 .30 .28 .31 .30 .28 .30 .29 .28 .29 .28 .27 .28 .27 .26 .26
.29 .27 .25 .28 .26 .25 .27 .26 .24 .26 .25 .24 .26 .24 .23 .23
.26 .24 .22 .26 .24 .22 .25 .23 .22 .24 .23 .21 .24 .22 .21 .20
.24 .21 .19 .23 .21 .19 .23 .21 .19 .22 .20 .19 .22 .20 .19 .18
.22 .19 .17 .21 .19 .17 .21 .19 .17 .20 .18 .17 .20 .18 .17 .16
.20 .17 .15 .19 .17 .15 .19 .17 .15 .18 .17 .15 .18 .16 .15 .14
.18 .16 .14 .18 .15 .14 .17 .15 .14 .17 .15 .14 .17 .15 .14 .13
.16 .14 .12 .16 .14 .12 .16 .14 .12 .16 .14 .12 .15 .13 .12 .12
.15 .13 .11 .15 .13 .11 .15 .12 .11 .14 .12 .11 .14 .12 .11 .10
ROOM CAVITY RATIO
Multiple Units (32W Triple Tube CFL)
Spacing Height Initial Watts
on to Lighted Foot- Per
Center Plane candles Sq. Ft.
6'
6' 23
1.00
12' 21
8'
6' 13
0.56
12' 12
10'
6' 9
0.36
12' 8
Spacing Ratio = 1.9 32W Triple Tube CFL
Illuminance (FC) Multipliers
For Incandescent: For Compact Fluorescent:
100 Watt = 0.7 26 Watt = 0.7
150 Watt = 1.2 42 Watt = 1.3
Application Data
Prepared For:
LIGHTOLIER
FALL RIVER, MA
DATE:
MAY 8, 2001
CERTIFIED TEST REPORT NO. 1415FR
COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER COMPACT FLUORESCENT PENDANT FIXTURE CAT. #4167U3CCAB
9” DIA. AMBER GLASS REFLECTOR
1-32W PLT TRIPLE TUBE PHILIPS LAMP. LUMEN RATING = 2400 LMS.
MAGNETEK BALLAST CAT. #C2642UNVSE
CANDLEPOWER SUMMARY
ANGLE MEAN CP LMS.
0 345
5 344 33
10 345
15 344 97
20 341
25 339 155
30 320
35 281 175
40 232
45 180 140
50 130
55 94 87
60 71
65 54 55
70 41
75 28 30
80 18
85 7 9
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 285 11.88 36.50
0-40 460 19.18 58.91
0-60 687 28.65 87.99
0-90 781 32.56 100.00
40-90 321 13.38 41.09
60-90 93 3.91 12.01
90-180 0 .00 .00
0-180 781 32.56 100.00
** EFFICIENCY =32.6% **
20% FLOOR CAVITY REFLECTANCE
% WALL REFLECTION