Owner's Manual
BASIC PROGRAMMING
OPTN
PROG
DIAG
FSTS
TS
T
E2
D1
C2
B2
Operation will 
vary depending 
on wiring type
SELECTOR DIAL
OPTN
PROG
DIAG
FSTS
TS
T
E2
D1
C2
B2
To prevent possible SEVERE INJURY or DEATH:
• Install a LiftMaster Monitored Entrapment Protection (LMEP) 
device.
• NEVER permit children to operate or play with door control 
push buttons or remote controls.
• Activate door ONLY when it can be seen clearly, is properly 
adjusted and there are no obstructions to door travel.
• ALWAYS keep door in sight until completely closed. NEVER 
permit anyone to cross path of closing door.
ATTENTION 
AVERTISSEMENT  AVERTISSEMENT 
AVERTISSEMENT 
WARNING WARNING 
CAUTION 
WARNING 
WARNING 
PRECAUCIÓN 
ADVERTENCIA 
ADVERTENCIA ADVERTENCIA 
TIMER-TO-CLOSE
Feature: Timer automatically closes door after preset time. All 
safety devices must be unobstructed.
Benefit: The door will automatically close after preset amount of 
time. Great for apartment buildings, fire stations and other 
applications where the end user wants the door to close 
automatically after a specified amount of time.
Requirements: Must have at least one LiftMaster Monitored 
Entrapment Protection (LMEP) device installed (refer to page 20). 
Wiring type must be set to TS, T or FSTS.
TO PROGRAM MANUALLY (METHOD 1):
1.  Close the door.
2.  Turn the selector dial to PROGRAM.
3.  Press and release the TIMER button on the logic board.
4.  Press and release the STOP button to clear the timer.
5.   Press and release the OPEN button for every second the 
operator should wait before attempting to close the door. Press 
and release the CLOSE button for every 15 seconds the 
operator should wait before closing the door.
6.   Press and release the TIMER button to complete programming. 
The OPEN/CLOSE button LEDs will flash to confirm the timer 
setting. The OPEN LED will flash once for every second 
programmed and the CLOSE LED will flash once for every 15 
seconds programmed.
7.   Turn the selector dial to desired timer wiring type (TS ,T or 
FSTS).
Example: To close the door after 70 seconds. Turn selector dial to 
PROGRAM, press and release the TIMER button, press and 
release the STOP button to clear the timer, press and release the 
CLOSE button four times for 60 seconds and press and release 
the OPEN button 10 times for 10 seconds. Press the TIMER 
button to finish programming the timer. Turn selector dial to 
desired timer wiring type. (TS, T, FSTS).
PROGRAM TIMER-TO-CLOSE BY EXAMPLE (Method 2):
TO PROGRAM:
1.  Close the door.
2.  Turn the selector dial to PROGRAM.
3.   Press and hold TIMER button for 5 seconds until OPEN and 
OLS flashes then release.
4.   Press and release the OPEN button and wait for the door to 
reach full open or mid stop position. 
5.   Wait for desired amount of time to pass. (An internal stop 
watch starts counting when the door stops moving.)
6.   Press and release the TIMER button, CLOSE button or STOP 
button to stop the timer. (TIMER SET LED will turn on.)
7.  Turn the selector dial to the desired wiring type (T, TS, FSTS).
NOTE: To read back the Timer-To-Close setting, turn the selector 
dial to DIAGNOSTIC and press the TIMER button. The OPEN LED 
will flash once for every second programmed and the CLOSE LED 
will flash once for every 15 seconds programmed.
To deactivate the timer from the open position press the STOP 
button. The timer will be reactivated on the next operation 
command. To deactivate the timer for more than one cycle, attach 
a switch to 11 and 12 (Common and Timer Defeat).
Reminders: FSTS wiring mode allows the Timer-To-Close to be 
activated by the Single Button Control (terminal 1) only. T wiring 
mode allows the door to attempt to close only one time for safety 
purposes.
OPTN
PROG
DIAG
FSTS
TS
T
E2
D1
C2
B2
Operation will vary 
depending on wiring type
SELECTOR DIAL
OPTN
PROG
DIAG
FSTS
TS
T
E2
D1
C2
B2
5










