Owner's Manual
Congratulations on purchasing a quality, LiftMaster Logic 4 Commercial Door Operator. Your new operator is capable of operating up to 
12 cycles per hour or 50 cycles per day. It is equipped with a built in radio receiver that is compatible with our existing 315 MHz product 
line as well as a Timer-to-Close (TTC) feature that can be enabled when LiftMaster Commercial Protector System
®
 is installed and aligned 
properly.
INTRODUCTION
INTRODUCTION TO PROGRAMMING
SLOT 1
RADIO
SLS
MRT MID TTC
DATA
24VAC
24VAC
LMEP:
EDGE:
OPEN
CLOSE
STOP
COMMON
RELAY A
RELAY B
SBC
MAS
COMMON
TIMER
DEFEAT
POWER
TIMER
ENABLE
123
FSTS
DIAG
OPTN
PROG
TTS
E2
D1
C2
B2
CLS
OLS
MID
REV
STD
SLOT 2
MOTOR
DIRECTION
3-PHASE
1-PHASE
Selector Dial
(used for programming 
and selecting wiring type)
Main Motor Control Harness Connection
Maximum Run 
Timer Button
Optional Auxiliary 
Card Receptacles
Mid Stop Learn Button
Timer-To-Close 
Learn Button
Radio Learn Button
Open Button
Close Button
Stop Button
Control Wiring 
Terminal Block
Motor Direction Jumper
Maintenance Alert 
System Button for 
Programming
Single Phase & 
Three Phase Jumper
BASIC PROGRAMMING
LOGIC BOARD OVERVIEW
LOGIC BOARD PUSH BUTTONS (OPEN, CLOSE, STOP)
Open, Close and Stop buttons are mounted directly on the logic 
board. Thus, making it easy to program as well as have door 
control at the electrical box. 
Either the stop control or a jumper MUST be wired between 
terminals 4 and 5 for the on board push buttons to function.
NOTE: Before programming the logic board, set the operator’s 
open and close limits. LEDs on the logic board are provided to 
assist setting the limits. As each limit is activated the 
corresponding LED will light up. The abbreviations are Open Limit 
Switch (OLS), Close Limit Switch (CLS) and Sensing Limit Switch 
(SLS). Refer to page 19 for limit switch adjustment instructions.
When power is applied to the operator, the following LED’s will 
illuminate: STOP, CLOSE, OPEN, LMEP, 24Vac, RADIO, DATA,
TIMER ENABLE, OLS MID, SLS, CLS, and MAS. Once the power 
up process is completed (approximately 2-3 seconds) only the 
appropriate LED’s will continue to be lit (i.e., STOP, 24Vdc, limit 
LED(s) if limit(s) is activated).
NOTE: When the power up process is over, the MAS LED will 
blink a code indicating the version of firmware. If the selector dial 
is in the DIAG, OPTN, or PROG position, the MAS will not provide 
this code. After the code has been provided the MAS LED will go 
out.
LOGIC BOARD LED OVERVIEW
Many programmable functions require that a LiftMaster Entrapment Protection (LMEP) device be installed in order to function. 
Refer to the Entrapment Protection section.