User Guide
9
POWER WIRING CONNECTIONS
1. Connect power wires coming from the main to the
captive terminal block in the electrical box enclosure
marked with the label shown below.
2. Be sure to run all power wires through the conduit
hole in the electrical box enclosure marked with the label
shown below.
POWER WIRING
TB2
CONTROL STATION WIRING
CONTROL WIRING CONNECTIONS
1. Connect control wires to the TB1 terminal block
located on the Printed Circuit Board (shown below).
GROUND WIRING
13 24AC-
12 24AC+
11 CMN
10 MAS
9 IR
8 REV
7 OPEN
6 CLOSE
5 STOP
4 CMN
3
2
1 SBC
ON THREE PHASE MACHINES ONLY
:
Incorrect
phasing of the power supply will cause the motor to
rotate in the wrong direction.
ANY MAINTENANCE OTHER THAN
PROGRAMMING OPTIONS IN THE OPERATOR
OR IN THE AREA NEAR THE OPERATOR MUST
NOT BE PERFORMED UNTIL DISCONNECTING
THE ELECTRICAL POWER AND LOCKING-OUT
THE POWER VIA, THE MAIN DISCONNECT
SWITCH. UPON COMPLETION OF
MAINTENANCE THE AREA MUST BE CLEARED
AND SECURED, AT THAT TIME THE UNIT MAY
BE RETURNED TO SERVICE.
4 Feet
Approximate
MOUNTING INSTRUCTIONS
Maintenance Alert
System
If light is Flashing,
it is time for routine
Door and Opener
Maintenance.
If light is Steady
On, call for
immediate service.
TM
Service every
________ cycles.
Control
Station
Optional
Controls
1. Mount Control Stations no further than (12”) from
each other.
2. Mount Control Stations (12”) from the door enclo-
sure.
3. Mount WARNING NOTICE beside or below the
Control Station.
4. Mount MAINTENANCE ALERT label to either side
of control station.
1. Connect earth ground to the chassis ground screw in
the electrical box enclosure marked with the label shown
below.
2. Use same conduit entry into the electrical box as the
power wiring.
IMPORTANT: THIS UNIT MUST BE PROPERLY
GROUNDED. FAILURE TO PROPERLY GROUND
THIS UNIT COULD RESULT IN ELECTRIC SHOCK
AND SERIOUS INJURY.
40-10033B
RADIO CONTROLS
INSTALL POWER WIRING & CONTROL STATION (CONT’D)
1
2
3
4
5
6
7
8
9
10
11
12
13
SBC
CMN
STOP
CLOSE
OPEN
REV
IR
MAS
CMN
24AC+
24AC-
SINGLE BUTTON CONTROL
INTERLOCK
INTERLOCK
COMMON
STOP
CLOSE
OPEN
REVERSE
INFRARED PHOTO EYES
MAINTENANCE ALERT SYSTEM
COMMON
24 VOLT AC
24 VOLT AC
On all models with B2 control wiring, a terminal bracket
marked R1 R2 R3 is located on the outside of the electri-
cal enclosure. Any commercial type LiftMaster brand
receiver may be mounted to this bracket. The operator
will then open a fully closed door, close a fully open
door, stop an opening door, and reverse a closing door
from the radio transmitter. In TS control wiring the oper-
ator will only open the door or reset the timer to close.
However, for additional door control from a 3 button
transmitter, a commercial three-channel radio receiver
(with connections for OPEN/CLOSE/STOP) is recom-
mended.
2. Be sure to run all control wires through the conduit
hole in the electrical box enclosure marked with the label
shown below.
3. Apply power to the operator. Press OPEN push button
and observe direction of door travel and then Press the
STOP button.
If door did not move in the correct direction, check for
improper wiring at the control station or between operator
and control station.
3
2