LO G IC OWNER'S MANUAL MODEL T C L O N TR O L FACTORY SET LOGIC CONTROL (VER. 2.0) INDUSTRIAL DUTY DOOR OPERATOR C2 Wiring See pages 15 and 16 for other wiring configurations PATENT PENDING The Maintenance Alert System TM allows the installer to set an internal Maintenance Cycle Counter. An LED on the 3-button station will signal when the set number of cycles is reached or when the opener requires immediate service.
Before attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. These instructions are intended to highlight certain safety related issues. These instructions are not intended to be comprehensive. Because each application is unique, it is the responsibility of the purchaser, designer, installer and end user to ensure that the total door system is safe for its intended use. TABLE OF CONTENTS SPECIFICATIONS Packing List . . .
SPECIFICATIONS MOTOR ELECTRICAL TYPE: .................................Continuous duty TRANSFORMER:.............24VAC Secondary HORSEPOWER: ................1/3, 1/2, 3/4 & 1 Hp CONTROL STATION: ......NEMA 1 three button station. OPEN/CLOSE/STOP W/ LED SPEED:...............................1725 RPM WIRING TYPE:.................C2 (Factory Shipped) Momentary contact to OPEN & STOP, constant presVOLTAGE: ..........................
OPERATOR PREPARATION POWERHEAD ATTACHMENT 1. Position the track assembly on the frame of the powerhead so that the motor side of operator is in back (away from door ). WARNING WARNING KEEP DOOR BALANCED. STICKING OR BINDING DOORS MUST BE REPAIRED. DOORS, DOOR SPRINGS, CABLES, PULLEYS, BRACKETS AND THEIR HARDWARE MAY BE UNDER EXTREME TENSION AND CAN CAUSE SERIOUS PERSONAL INJURY OR DEATH. CALL A PROFESSIONAL DOOR SERVICEMAN TO MOVE OR ADJUST DOOR SPRINGS OR HARDWARE. 2.
INSTALLATION INSTRUCTIONS IMPORTANT NOTE: Before the operator is installed, be sure the door has been properly aligned and is working smoothly. Although each installation will vary due to particular building characteristics, refer to the following general procedures to install the operator. MOUNT HEADER BRACKET The trolley operator is generally mounted over the center of the door. However, off center mounting may be required due to interfering structures or location of door stile / top section support.
INSTALLATION INSTRUCTIONS STRAIGHT ARM ATTACHMENT 1. Fully close the door and move the trolley slider to within (2”) two inches of the front idler. OPERATOR SUPPORT 1. The illustration below shows a typical method of hanging the operator from the ceiling. Each installation may vary, but in all cases side braces should be used for additional strength. 2. Latch the straight door arm to the fixed roll pin in the trolley carriage. Make sure the open side of notch on the arm faces the doorway. 2.
ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL) PHOTO EYES & SENSING EDGES Sensing devices supplied for door industry type operators with an isolated normally open (N.O.) dry contact output are compatible with your operator. This includes pneumatic and electric edges, and through beam and retro reflective photo eyes. If your door does not have bottom safety photo eyes or a sensing edge and you wish to add a safety device to your application, please contact your local LiftMaster Authorized Dealer.
INSTALL POWER WIRING & CONTROL STATION Before installing power wiring or control stations be sure to follow all specifications and warnings described below. Failure to do so may result in severe injury to persons and/or damage to operator. The operator electrical box is only to be accessed by trained “LIFTMASTER” technicians. If service is required contact your local LIFTMASTER dealer. Do not install any wiring or attempt to run the operator without consulting the wiring diagram.
INSTALL POWER WIRING & CONTROL STATION (CONT’D) 1 2 3 4 5 6 7 8 9 10 11 12 13 2. Be sure to run all power wires through the conduit hole in the electrical box enclosure marked with the label shown below. ON THREE PHASE MACHINES ONLY: Incorrect phasing of the power supply will cause the motor to rotate in the wrong direction. GROUND WIRING 13 24AC- 12 24AC+ 11 CMN 10 MAS 5 STOP 4 CMN 3 2 1 SBC TB2 9 IR CONTROL WIRING CONNECTIONS 1.
EMERGENCY DISCONNECT SYSTEM WARNING DOOR ARM IS RELEASED FROM TROLLEY WHEN EMERGENCY DISCONNECT OPENS. TO AVOID BEING STRUCK BY DOOR ARM, DO NOT STAND UNDER THE ROPE OR DOOR ARM WHEN PULLING THE EMERGENCY RELEASE.
BRAKE ADJUSTMENT A solenoid brake is standard on 3/4 and 1 horsepower models, and is optional on 1/3 and 1/2 horsepower models. The brake is adjusted at the factory and should not need additional adjustment for the the life of the friction pad. Solenoid Brake System Replace friction pads when necessary. Refer to the illustration for identification of components for the solenoid type brake system. Friction Pads Plate Assembly Solenoid Release Lever CLUTCH ADJUSTMENT & AUXILIARY REVERSAL SYSTEM 1.
STANDARD POWER & CONTROL CONNECTION DIAGRAM Logic Control Board (VER. 2.0) - 115V, 208, 230V, 1Ph Logic Control Board (VER. 2.
LOGIC CONTROL (VER. 2.0) 1 PHASE WIRING DIAGRAM 1837-1 230 VOLT MOTOR CONNECTION NOTE: CONTACTOR 1PH / 3 PH JUMPER SHOULD BE IN 1 PH POSITION 115 VOLT MOTOR CONNECTION Note: 1) See Owner’s Manual for Dip Switch Functions and Programming Procedures 2) TO REVERSE MOTOR DIRECTION 115 VOLTS: ALWAYS EXCHANGE PURPLE & GRAY ALL VOLTS & PHASES. 230 VOLTS: INTERCHANGE PURPLE (E10) & GRAY (E15) WIRES AT LOGIC BOARD. * - BLUE WIRE MUST BE INSULATED ON 230V 1PH.
LOGIC CONTROL (VER. 2.0) 3 PHASE WIRING DIAGRAM 1837-3 380/460 VOLT MOTOR CONNECTION NOTE: CONTACTOR 1PH / 3 PH JUMPER SHOULD BE IN 3 PH POSITION 230 VOLT MOTOR CONNECTION Notes: 1) See Owner’s Manual for Dip Switch Functions and Programming Procedures 2) TO REVERSE MOTOR DIRECTION: INTERCHANGE ANY 2 OF THE 3 POWER WIRES AT L1, L2 & L3, OR EXCHANGE PURPLE & GRAY MOTOR LEADS AT BOARD CONNECTIONS E17 & E6 (3PH UNITS ONLY). **- Transformer Primary Voltage same as Line Voltage.