SLMAX/SW2200 Programming Instructions Contents SLMAX/SW2200 Programming Controls __________________________ 3 Viewing the Gate’s Current Status ________________________________ 3 Programming the Single Button Functions__________________________ 4 Setting the Gate Open/Close Limits _______________________________ 6 Setting the Gate Operator Speed __________________________________ 7 Setting the Deceleration Limits ___________________________________ 9 Setting the Entrapment Level ________________________
LiftMaster 3 SLMAX/SW2200 Programming Controls Programming occurs on a 5-button, 2-LED membrane switch located on top of the control box (see Figure 1). Programming instructions appear on a 2-row, 16-character LCD screen. The OPEN LIMIT LED flashes during Open Limit programming. LCD SCREEN Sentexsystems Sentex Press the ENTER button to select a program or save program settings. Use the MENU Buttons to scroll up/down the programming menu.
SLMAX/SW2200 Programming Instructions Programming the Single Button Functions FACTORY DEFAULT: OPENING = STOP, NO TIMER RESET CLOSING = (None—button has no effect) MID-STOP = MID-STOP OPEN The Single Button (connected at the J8 input connector) programming feature allows you to configure the single button function (i.e., how the gate reacts after you press the single button). You may program the single button function to perform the actions outlined in Table 2.
LiftMaster 5 Set the Single Button Function To set the single button function, follow the steps below: PROCEDURES 1 Pressing the MENU buttons (!"), locate the SINGLE BUTTON option and press ENTER. DISPLAY PROMPT SINGLE BUTTON 2 For the first setting, press (–) or (+) to select the desired option and press ENTER to save. Options: Stop—Stop, No Tmr Rst—Open Only OPENING (OPTION) 3 For the second setting, press (–) or (+) to select the desired option and press ENTER to save.
SLMAX/SW2200 Programming Instructions Setting the Gate Open/Close Limits NO FACTORY DEFAULT SETTING This feature allows you to set the gate’s open or close limits without utilizing limit switches. You are essentially setting the operator so it knows how far to open and close its gate. NOTE: After a power outage or operator gate disengagement, the operator will retain its limit settings. Also, to stop the gate while setting the limits, release the (+) or (-) buttons.
LiftMaster 7 Setting the Gate Operator Speed This feature allows you to change the speed of the gate. Please note that max speed (normal gate speed) and min speed (decelerated gate speed) have their own minimum and maximum range. For the SW2200, Table 4 provides speed settings based on the total amount of time it takes the gate to fully open or close.
SLMAX/SW2200 Programming Instructions NOTE: The open/close time settings in Table 4 are valid if: (1) You install the gate with the gate dimensions recommended in the installation manual. -and(2) The Open and Close Deceleration Limits are programmed at the minimum (100) setting. -and(3) The Min Gate Speed is programmed to 120.
LiftMaster 9 Setting the Deceleration Limits This feature allows you to set the distance during which the gate starts to slow down prior to stopping at the open or close limit. Set the Open Deceleration Limit FACTORY DEFAULT = MEDIUM To set the Open Deceleration Limit, follow these steps: PROCEDURES DISPLAY PROMPT 1 Pressing the MENU buttons (!"), locate the OPEN DECEL LIMIT option and press ENTER. OPEN DECEL LIMIT 2 Press (–) or (+) to set the distance.
SLMAX/SW2200 Programming Instructions Setting the Loop Detector FACTORY DEFAULT = LOOP INPUT A: OPEN LOOP LOOP INPUT B: SAFETY LOOP LOOP INPUT C: SHADOW LOOP This feature allows you to program the desired loop function using the J4 inputs (A, B, and C). Before setting the loop detector, check which loop types are connected to the J4 inputs. EXAMPLE: Input A may be connected to an Open Loop Detector. If so, set Input A on J4 to Open Loop.
LiftMaster 11 Enabling/Disabling the Operator Warning FACTORY DEFAULT = OFF This feature allows you to enable or disable the operator alarm that warns people with beeps when the gate is moving. NOTE: If you enable the operator warning, and when the gate is prompted to open, the alarm will sound immediately, but the gate will start opening after a programmed number of seconds (1-9).
SLMAX/SW2200 Programming Instructions Setting the Electric Lock Delay FACTORY SETTING = OFF All gates installed with a maglock (connected to the JP6 connector/input) may have the electric lock delay function programmed into the system. This delays the gate from opening for a programmed number of seconds (1-10) when the operator is prompted to open. After the delay, the operator will de-energize the maglock (allowing the gate to unlock) and open the gate.
LiftMaster 13 Factory Default Settings The SLMAX and SW2200 come programmed with factory default settings so that you won’t have to program each step when an operator is first installed. If the operator has been installed recently, review the factory default settings (Table 5) and decide which settings you’d like to change. You may also reset the existing settings to their default parameters.
COPYRIGHT 2001 ALL RIGHTS RESERVED This document is protected by copyright and may not be copied or adapted without the prior written consent of LiftMaster. This documentation contains information proprietary to LiftMaster and such information may not be distributed without the prior written consent of LiftMaster. The software and firmware included in the LiftMaster product as they relate to this documentation are also protected by copyright and contain information proprietary to LiftMaster.