User Guide

ADJUST LIMITS
TO AVOID SERIOUS PERSONAL INJURY OR
DEATH FROM ELECTROCUTION, DISCONNECT
ELECTRIC POWER BEFORE MANUALLY
MOVING LIMIT NUTS.
MAKE SURE THE LIMIT NUTS ARE POSITIONED
BETWEEN THE LIMIT SWITCH ACTUATORS
BEFORE PROCEEDING WITH ADJUSTMENTS.
1. Depress open limit switch. The operator should stop.
2. To increase door travel, spin nut away from
actuator. To decrease door travel, spin limit nut
toward actuator.
3. Adjust open limit nut so that door will stop in open
position with the bottom of the door even with top of
door opening.
4. Repeat Steps 1 and 2 for close cycle. Be sure close
limit actuator is engaged as door fully seats at the
floor.
If other problems persist, call our toll-free number for
assistance - 1-800-528-6563.
CLOSEOPEN
ADLSSLS
OLS
CLS
Open Limit
Nut
Travel Nut
Retainer
Close Limit
Nut
Actuator
Actuator
Open Limit
Switch
Close Limit
Switch
FOR HTC
Press Travel Nut Retainer
DOWN Toward Frame
TO DISENGAGE
DOOR HEIGHT + 4' - 5/8"
16-5/8"
MIN. CLEARANCE
OF 2" FROM HIGH
ARC OF DOOR TO
BOTTOM OF TRACK
13-7/16"
2-1/32"
5-1/2"
3-15/16"
3/4"
1-3/8"
26-5/8"
17-1/4"
MAX.
12-1/8"
Room required to open
hinged electrical box
7-1/2 "
2
REFER TO PAGE 2 OF HT OWNER'S MANUAL
NEMA UNIT
WARNING