User Guide

4
ELECTRICAL ENCLOSURE WALL MOUNTED
STARTER MODELS HJR/GJR
13
1
/2
"
6
5
/8
"
6
13
/16
"
9
3
/32
"
9
7
/8
"
Important Notes
Please Read Before Proceeding
1. Make sure that the serial number on the operator limit switch cover matches the serial
number on the electrical enclosure cover.
2. All field installed wiring must be run using U.L. listed conduit and connectors.
3. Install high voltage wiring and 24VAC (control and limit) wiring in separate conduits.
Installation
1. Install the operator motor and frame assembly according to the Owner's Manual for your
model operator, (either GJ or HJ).
2. Securely attach the electrical enclosure to the wall adjacent to and within sight of the door
and operator. See Figure 1.
3. Refer to Figure 1 and wiring diagrams for locations of conduit and wiring connections.