User Guide

VOLTAGE/PHASE
SINGLE
PH
THREE
PH
JUMPERS
& RELAYS
X X
JA X
JB X X
JC X X X X
JE X X
J1 X X X
J2 X X X
120V LR RELAY X
240V IR RELAY X
INLINE OVERLOAD X X
**
X X
TIME CAPSULE*** X
* OPTIONAL ADJUSTABLE TIMER FUNCTION
AVAILABLE TO ACTIVATE WARNING SYSTEM
PRIOR TO AUTOMATIC DOOR CLOSING
(REQUIRES 115V POWER SOURCE IF
OPERATOR IS NOT 115 VOLT.)
** MOTORS AT THESE RATINGS ARE SUPPLIED
AS STANDARD WITH AN INTERNAL,
AUTOMATIC RESETTING OVERLOAD. (IN LINE
OVERLOADS ARE OPTIONAL)
*** L5 SEC. DELAY TO OPEN TIME CAPSULE
ALLOWS LARGE DOORS TIME TO SETTLE
DOWN BEFORE REVERSING TO OPEN
POSITION.
NOTE: ELECTRIC EYES AND LOOP
DETECTORS ARE NOT TO BE USED AS
SENSING DEVICES TO STOP OR REVERSE
WHEN TS OR STS WIRING TYPES ARE USED.
JUMPERS,
RELAYS
SWITCHES &
TIMERS
WIRING TYPES * * * *
B C D E B1 C1 D1 B2 C2 E2 S T ST TS STS
J3
X X X X
J4
X X X X X X X X
X X X X X X X
J6
X X
J7
X X X X X X X X X X X X X
J8
X X X X X X X X
J9
X X X
J10
X X X X X X X X X
J11
X X
SENSING LIMIT
X X X X X X X X X X X X
X X X X X X X X X X X
AUX DEVICE
LIMIT
X X X X X X
TIMER IMPULSE
RELAY
X X X X
TIMER LATCHING
RELAY
X X X X
TIMER
X X X X
3 BUTTON
STATION
X X X X X X X X
2 BUTTON
STATION
X X X X
1 BUTTON
STATION
X X X
OVERLOAD AND CAPACITOR VALUES
SINGLE PHASE THREE PHASE
OVERLOAD VALUES CAPACITOR VALUES OVERLOAD VALUES
115 VOLT
230 VOLT CENTURY FRANKLIN 230 VOLT 460 VOLT
HP AMP PART
NO.
MFD/VAC PART
NO.
MFD/VAC PART
NO.
AMP PART
NO.
AMP PART NO.
AMP
PART
NO.
1/3
7
452431 3.5 452429 378-
455/125
453212 386-
464/110
453213 2.20** 453377 1.00** 453375
1/2 10 452433 5 452430 378-
455/125
453212 386-
464/110
453213 2.60 453377 1.40 453375
1 15 452434 8 452432 378-
455/125
453212 431-
518/110
453214 4.00 453378 1.95 453376
2
- - - - - - - -
6.20 453380 3.20 453378
3
- - - - - - - -
10.50 458001 5.20 453380
MOTOR REPLACEMENT
PART NUMBER
HP 1 PHASE 3 PHASE
1/3 451347 451350
1/2 451348 451351
1 451349 451352
2 -------- 451353
JUMPER CHART