Instructions / Assembly

11
TEST MODES AND ADJUSTMENTS
Your grill l is already set up from the factory and ready to grill below are the test modes
available and adjustments
1. Test Mode - With grill OFF, press and hold the Probe Temp and Temp Down buttons
to enter the button test Mode until all digital display and LEDs turn on . Press Pro-
beTemp button it displays “S-1”, press I/O button it displays “S-2”, press Temp Down
button it displays “S-3”,press Temp Up button it displays “S-4”, Press Temp Display
button it display “S-5”, Each additional press of the Probe Temp button will advance
you through below next function test.
2. Displaying “AUG”is test mode for your auger motor. You should be able to look in your
grills fire pot and see the end of the auger turning very slowly.
3. Displaying “IGN” is test mode for your grills ignition system. You should be able to
look into grills fire pot and see your igniter begin to glow within a few minutes. DO
NOT TOUCH THE IGNITER.
4. Displaying “FAN” is test mode for your grills blower fan. You should be able to hear
the fan blowing.
5. Displaying Actual Grill Temp
6. Displaying Actual Meat Probe Temp A
7. Displaying Actual Meat Probe Temp B
8. Return to OFF state