User's Manual
BHS-i100 Installation and Programming Instructions
46
Delay using the Standard Programming Menu. Program a delay
of 1-250 seconds.
Exit Tone Enable. Causes the Keypad to beep during the exit
delay. This may be disabled at the Keypad. Program “yes” to
enable this tone for the Keypad in question.
Expiration Date. The date that the system automatically reverts
to Local Fire mode. Reporting is discontinued and only local
fires alarms are announced. Program the date of your choice.
To prevent the system from reverting, program a date far in the
future, such as the default value 09/09/9999.
---- F ----
Fire Alarm (Report). Tells the central station (or other
communicator) that an alarm has occurred on a fire zone or that
the emergency fire key has been pressed. Program “yes” to
enable this type of reporting.
Fire Cutoff Minutes. How many minutes the bell/siren outputs
sounds following a fire alarm. Program a time of 0-255 minutes,
where 0 latches the sounder.
Fire Pattern. The cadence that annunciates alarms on fire
zones. There are seven output patterns available for each alarm
type; Temporal Code 3 is used for fire alarms, including the
Emergency Fire Key. The cadence format selected would
depend upon the country where the system is installed. Both
US and Canadian versions of Temporal Code 3 are available.
Choose the desired cadence from the list of options.
Fire Trouble (Report). Tells the central station (or other
communicator) that a trouble condition exists on a fire zone.
Program “yes” to enable this type of reporting.
Firmware Version. See Version (Firmware).
FOB Panic is Medical. Triggers a medical emergency when
the system receives a panic signal from the Keychain Remote.
If disabled, a police emergency is signaled instead. Program
“yes” to set the panic to medical emergency, and “no” to leave it
as a police emergency.
---- G ----
Gas Alarm (Report). Tells the central station (or other
communicator) that an alarm has occurred on a CO/Gas zone
or that the emergency CO/Gas key has been pressed. Program
“yes” to enable this type of reporting.
Gas Cutoff Minutes. How many minutes the bell/siren outputs
sounds following a CO/Gas alarm. Program a time of 0-255
minutes, where 0 latches the sounder.
Gas Pattern. The cadence that annunciates alarms on CO/Gas
zones. There are seven output patterns available for each alarm
type. The cadence format selected would depend upon the
country where the system is installed. Choose the desired
cadence from the list of options.
GE or Grid Extender. A Grid Extender is a device such as a
Keypad, Signal Extender, or Programmer. All of these devices
can join the grid network in the customer’s home or small office.
---- H ----
Host Check-In (User 9). The user code that allows the
customer to initiate a call to the Imagine. After the call is
connected, the code is changed to another random code that is
stored in the Imagine database. The new code is given to the
customer by a Customer Care operator when needed.
----I ----
Installer Login (Report). Tells the central station (or other
communicator) that the system has been placed in
programming mode. Program “yes” to enable this type of
reporting.
Installer Name. Describes the installer in additional detail for
easier identification. Enter up to 24 letters or numbers.
---- K ----
Keypad #. The number automatically assigned to the system
Keypad when you select the Learn Devices option from the
Home Menu.
Keypad Name. Describes the Keypad in additional detail for
easier identification. Enter up to 24 letters or numbers.
---- L ----
Latching Chime. Causes the chime feature to be temporarily
suspended when the system is armed, then reinstated when the
system is disarmed. The suspension occurs regardless of which
arming mode the customer chooses. Program “yes” to configure
the chime to be automatically reinstated.
Line Cut Monitor Enable. Instructs the system to monitor the
telephone line for open conditions (line cuts). Program “yes” to
detect line cuts.
Long Dist Access. An extension of the dial string used to
automatically dial a long distance access code when a phone
line is configured for long distance blocking.
Low Battery (Report). Tells the central station (or other
communicator) that the system’s standby battery has dropped
below a pre-defined level, generally around 3.1 VDC. Program
“yes” to enable this type of reporting. (The Low Battery Report
topic in the View/Edit System menu must also be enabled.)
Low Battery Report Enable. A global option that allows Low
Battery reporting to the central station (or other communicator)
to be turned on or off without programming individual Comm
devices. Program “yes” to enable this reporting.
---- M ----
Master Code. The code that is required to add or change the
user codes of auxiliary users (Users 1 - 8). The master user
code (User 13) can be changed by customer only if the Master
Code Reprogram Enable topic is enabled.
Medical Alarm (Report). Tells the central station (or other
communicator) that medical alarm has occurred. The alarm can
be triggered by a medical pendant or by pressing the
emergency medical key. Program “yes” to enable this type of
reporting.
Medical Pattern. The cadence that annunciates an alarm
condition on a medical zone or the emergency medical soft
zone. The normal medical cadence is two seconds on and two
seconds off. Choose the desired cadence from the list of
options.