User's Manual
BHS-i100 Installation and Programming Instructions
40
Day / Night Zone
7.3.7 Medical Zone
A pushbutton device on this 24-hour zone type can be used to
summon help in a medical emergency. An alarm is triggered
when the medical zone is faulted. The Keypads buzz to
annunciate the alarm.
7.3.8 Assault Zone
A pushbutton device on this 24-hour zone type can be used to
summon the police when a crime is in progress. An alarm is
triggered when the assault zone is faulted. The sirens sound to
annunciate the alarm.
7.3.9 Silent Assault Zone
A pushbutton device on this 24-hour zone type can be used to
summon the police when a crime is in progress. Like the assault
zone, an alarm is triggered when the silent assault zone is
faulted. However, in this zone type, the sirens do not sound.
7.3.10 Auxiliary Zone
A monitoring device on this 24-hour zone type can be used to
summon help when a potentially dangerous condition exist,
such as frozen pipes, or water leaks. A push button device on
the zone can also be used to trigger silent report tampers. An
alarm is triggered when the auxiliary zone is faulted. However,
no sirens sound.
7.3.11 Follower Delay Zone
A follower delay zone is typically used for motion sensors
located along the route that the customer takes to leave the
building. A follower delay zone is also a good substitute for an
instant zone, because the twenty second delay that occurs
before an alarm sounds can prevent false alarms. The flowchart
shows the conditions under which a fault on a follower delay
zone results in an alarm.
Follower Delay Zone
7.3.12 Fire Zone
Zones that monitor smoke or heat detectors should be
programmed as fire zones. Fire zones are 24-hour zones. They
are always supervised with normally-open contacts.
An alarm is triggered whenever the zone is faulted. The
systems sirens sound. If an alarm on a fire zone and an alarm
on another type of zone occur at approximately the same time,