BHS-i100 Installation and Programming Instructions
39
Secondary Delay Zone
7.3.4 Instant Zone
Zones that protect areas that are not common points of entry
can be programmed as instant zones. An example would be an
interior motion detector. The flowchart shows the conditions
under which a fault on an instant zone results in an alarm.
Instant Zone
7.3.5 Follower Zone
A follower zone is typically used for motion sensors located
along the route that the customer takes to leave the building.
The flowchart shows the conditions under which a fault on a
follower zone results in an alarm.
Follower Zone
7.3.6 Day / Night Zone
When a Day/Night Zone is used to monitor line cuts, the zone
behaves in the following ways when a line is cut:
If the system is armed, the siren sounds.
If the system is disarmed, the Keypad displays a trouble
message and beeps. The user can silence the beeping
manually.
The flowchart shows the conditions under which a fault on a
Day/Night zone results in an alarm.