User's Manual

BHS-i100 Installation and Programming Instructions
37
The systems come defaulted in the SIA mode and contain some
programming areas, which are not available in the Brinks
Default mode. Below are the default values.
Advanced Menu | Global Parameters | System Menu
Cross Zone Time: 20 seconds
Swinger Trips
5
: 1
Automatic Swinger Reset
5
: Disabled
Restoral Minutes
5
: Default is 5 minutes
Advanced Menu | Device Menu | Zone/Sensor Menu
Cross Zone Enable: No
Swinger Bypass
5
: Enabled for Non-Fire zones, disabled for Fire
zones.
Fire Verification Enable: No.
Dialer Delay Enable: Enabled for Non-Fire zones, Disabled for
Fire zones
Standard Menu
Exit Time: 60 seconds (Residential), Entry Time: 30 seconds
Advanced Menu | Global Parameters | System Menu
Exit Time Restart: Yes
Automatic Motion Off (Auto stay arm on unvacated premise
feature): Yes (System automatically arms with Motions Off if no
Exit/Entry zone is opened during the Exit Delay countdown.)
Dialer Delay (Abort Window): 30 seconds
Double Dispatch Enable: Yes (Requires the user to press the
Fire, Medical, or Panic emergency key twice within three
seconds to trigger a soft zone alarm.)
Advanced Menu | Global Parameters | Account Menu
Alarm Cancel Enable: Yes
Advanced | Comm Menu | Vw/Edt Comm
Exit Error Event Report: Yes
Recent Closing Event Report: Yes
Standard Menu | User Codes
Duress Code 12 – Blank
Standard Menu | Dial Prefix
Area Blank - used to enter call waiting digits/characters
Additional Notes and Cautions:
1. The aggregate of the Entry Delay and Abort Window
(Dialer Delay) shall not be programmed to exceed one
minute.
26. Caution:
A call waiting cancel on a non-call waiting line will
prevent successful connection to the central station.
27. The system will not allow Duress Codes to be
programmed as an existing user access code plus one ( +
1).
28. Recent Closing interval is always enabled.
29. Automatic Swinger Reset (default disabled) - If enabled,
zones shut down due to swinger bypass will automatically
reset after 48 hours with no trips on any zone. Zones can
also be manually reset.
Swinger Bypass - If enabled, the zone will shut down after
the programmed value in the Swinger Trips area.
Restoral Minutes - sets the time that a particular zone
must be restored before it causes another alarm if re-
violated.
30. Additional Keypads may be required so that Exit/Entry
annunciations can be heard within the entire protected
area.
31. System Test is initiated under the installer programming
mode under Test | Installer Test.
32. If Cross Zoning is enabled, do not Cross Zone Exit/ Entry
and Fire zone types.