User's Manual

BHS-i100 Installation and Programming Instructions
29
3.6 Programmable Options Lists
The following sections are lists of the programmable options available for some topics.
3.6.1 List A: Zone types
A zone can be configured in any of the following ways:
- Unconfigured
- Entry/Exit
- Secondary
- Instant
- Follower
- Follower Delay
- Day/Night
- Medical
- Assault
- Silent Assault
- Auxiliary
- Duress
- Fire
- Local
- Carbon Monoxide
3.6.2 List B: Output patterns
The system’s output patterns can be configured in any of the
following ways:
- Silent
- Steady
- Pulse 1s/1s
- Temporal Code 3 USA
- Temporal Code 3 CAN (Canada)
- Blast 1s
- Chirp 100ms
- Medical
3.6.3 Automatic Zone Configurations
In some cases, selecting one programming option causes the Programmer to reconfigure the settings of other options automatically.
When you specify a zone type, a number of other zone-related topics are automatically programmed. For example, when you program a
zone to be a fire zone, its Alarm Output Pattern is automatically set at Temporal Code 3 (USA), with a latched cutoff time.
Zone Type Default Name Trouble
Reporting
Chime Motion
Bypass
User
Bypass
Alarm
Output
Pattern
Cutoff
Time
Entry
Delay
Dialer
Delay
Unconfigured N/A
1. Entry/Exit Door No Yes No Yes Steady 5 min. 40
sec.
Yes
2 Secondary
Delay
Garage Door No Yes No Yes Steady 5 min. 180
sec.
Yes
3. Instant Window No Yes No Yes Steady 5 min. N/A Yes
4. Follower Motion No No Yes Yes Steady 5 min. N/A Yes
5. Day/Night Gun Cabinet or
Line Cut (Zone 61)
No No No Yes Steady 5 min. N/A Yes
6. Medical Medical Button
(Zone 63)
No No No No Pulsing 5 min. N/A No
7. Assault
(Police)
Panic Button (Zone
64)
No No No No Steady
Indefinite
(Latched)
N/A No
8. Silent
Assault
Silent Holdup No No No No Silent Indefinite
(Latched)
N/A No
9. Auxiliary Auxiliary No No No Yes Steady 5 min. N/A No
10. Follow
Delay
Motion No No Yes Yes Steady 5 min. 20
sec.
Yes
11. Fire Smoke Detector or
Fire Button (Zone
62)
Yes No No No Temp
Code 3
USA
Indefinite
(Latched)
N/A No
12. Local Local No No No No Blast
(1sec.)
0 min N/A N/A
13. Carbon
Monoxide
CO Detector No No No No Pulsing Indefinite N/A No