User's Manual
BHS-i100 Installation and Programming Instructions
23
To Skip: If you do not wish to program a
global entry delay, press the [\/] key
to scroll to the next menu item.
Menu Item 5: User Codes
Information sought: Do you wish to change any of the
system’s user codes?
Default value: Only the Master and the Host
Check-in codes have default values
(123 and 876, respectively); all
other codes are blank. For all
codes the number of digits in the
user code is determined by the
User Code Length topic
(Advanced | Account | User Code
Length or Standard | User Code
Len).
To Configure: If you wish to create or change a
code, press the [Enter] key to
begin. You see:
Select User Number: input the
number of the user code you wish
to change, then press the [Enter]
key. If the user does not exist, you
are asked if you wish to create the
user. Press “1” to create the user,
or “2” to select a different user
number.
User Name: if you wish to input a
user’s name press the [Enter] key,
input the name, then press the
[Enter] key again to write it to
memory. The default names are as
follows:
Users 1 - 8 are blank
User 9 - Host Check-in
User 10 - Special Bypass User
User 11 - Duress User
User 12 - Master User
Access Code: to change or enter a
new code, press the [Enter] key,
input the new access code, then
press the [Enter] key again to write
the code to memory.
To Skip: If you do not wish to change a
code, press the [\/] key to scroll to
the next menu item.
Menu Item 6: Line Cut
Information sought: Do you wish to change the current
configuration of Line Cut
monitoring?
Default value: Not monitored.
To Configure: If you wish to change the setting,
press the [Enter] key to switch to
the data-entry mode. Use the [/\] or
[\/] keys to change the programmed
value, then press the [Enter] key to
write the change to memory.
To Skip: If you do not wish to change the
current setting, press the [\/] key to
scroll to the next menu item.
Menu Item 7: Op/CI Reports
Information sought: Should the system report openings
and closings to the central station
(Alarm Receiver)?
Default value: No (Opening and closing events
are not reported.)
To Configure: To change the programming, press
the [Enter] key to change to data-
entry mode. Use the [/\] or [\/] keys
to change the programmed value,
then press the [Enter] key again to
write the change to memory.
To Skip: If you do not wish to change the
current configuration, press the [\/]
key to scroll to the next menu item.
Menu Item 8: User Code Length
Information sought: What is the user code length?
Default value: 3 digits
To Configure: To change the user code length,
press the [Enter] key to begin.
You will see User Code Length #3.
Press the [Enter] key, press the
[Back] key to erase the
programmed number, then type in
the desired user code length. Valid
range is 3 - 8 digits.
If you enter a value outside the
valid range, you will see an error
message. Press the [Enter] key to
return to the previous screen.
Next, press the [Enter] key to write
the change to memory and return
to the Standard Menu.
To Skip: If you do not wish to change the
current setting, press the [\/] key to
scroll to the next menu item.
3.5.4 Home Menu Option 4: Advanced Menu
Advanced Programming Tree. The first three levels of the
Advanced Menu tree are shown in the illustration on the
following pages. You will find a definition of each topic in
Appendix B: Glossary of Programmable Topics.