3.5 Programming Options
3.5.1 Home Menu Option 1: Set Defaults
The first option of the Home Menu is Set Defaults. This option
allows you to revert the BHS-i100's programming to either the
Brinks defaults or SIA (SIA CP-01-2000 Standard) compliance
defaults. (Factory default is SIA Compliant mode.)
When you select Set Defaults, you will be asked to confirm the
request by pressing the [1] key or cancel it by pressing the [2]
key. You will then be asked to select the Compliance Mode.
Press [Enter], then press the [/\] and [\/] keys to show Brinks or
SIA. Press [Enter] again to make your selection. The defaults for
each programmable topic are listed in the Standard and
Advanced Programming portions of this section.
Refer to Appendix D for more information on the SIA false alarm
reduction settings.
3.5.2 Home Menu Option 2: Learn Devices
The second option of the Home Menu is Learn Devices. This
option allows you to Add, Edit or Delete any device in the BHS-
i100’s system.
Menu Item 1: Learn GE
Information sought: Do you wish to learn (register) one
or more Grid Extenders (Keypads
or Signal Extenders) into the
system?
Default Value No GEs learned.
To Configure: Select the Learn GE menu option
from the Home Menu | Learn
Devices Menu. Registration will be
enabled for only 60 seconds. Press
and hold “5”, “6”, on the new
keypad, or press and hold the
Registration button on the new
Signal Extender. See section 2.9.4
and 2.9.5 for detailed steps. Upon
successful registration, the
Programmer and the Keypad will
each chirp.
The registration must be confirmed
on the Keypad or Signal Extender.
To Skip: If you do not wish to learn a Grid
Extender, press the [\/] key to scroll
to the next menu item.
Menu Item 2: Learn InGrid Sensor
Information sought: Do you wish to learn (register) one
or more InGrid Sensors?
To Configure: If you wish to register an InGrid
Sensor, press the [Enter] key to
begin. See section 2.10 for detailed
steps. Registration will be enabled
for only 60 seconds. While holding
the Programmer near the clip, snap
the InGrid Sensor into the clip. The
Sensor will automatically register
and both the Programmer and the
Keypads will triple beep.
If the Sensor fails to register within
60 seconds, the Programmer will
leave registration mode
automatically. If a system detects
two registration bursts during the
Sensor registration mode it will not
register either Sensor and the
Programmer will leave registration
mode automatically.
The registration must be confirmed
by faulting the Sensor using the
magnet.
A zone number and type must be
configured for the Sensor.
To Skip: If you do not wish to learn any
InGrid Sensors, press the [\/] key to
scroll to the next menu item.
Menu Items 3-6: Learn Ademco Sensors (Door/Window,
Glass, Motion, and Fire)
Information sought: Do you wish to learn (register) one
or more Ademco Transmitters?
Default Value No Ademco sensors learned.
To Configure: If you wish to register an Ademco
Transmitter, press the [Enter] key
to begin. See section 2.12.2 for
detailed steps. Registration will be
enabled for only 15 seconds. While
holding the Programmer near the
clip, fault the Ademco Transmitter.
(Note: The 5808LST Smoke
Detector can be faulted by pressing
the recessed test button on the
front of the unit. The 5800 Motion
Sensor can be faulted by moving
your hand in front of the sensor.
The 5853 Glassbreak Detector can
be faulted by tapping it with a pen.)
The Ademco Transmitter will
automatically register and both the
Programmer and the Keypads will
triple beep.
If the Ademco Transmitter fails to
register within 60 seconds, the
Programmer will leave registration
mode automatically. If a system
detects two registration bursts
during the Transmitter registration
mode it will not register either
Transmitter and the Programmer
will leave registration mode
automatically.
The registration must be qualified
by faulting the Transmitter.
A zone number and type must be
configured for the Transmitter.