User's Manual

BHS-i100 Installation and Programming Instructions
13
number which is currently in use, the Programmer will
display:
OK to overwrite
Siren 1?
1=YES 2=NO
8. After the siren number has been selected, the Programmer
will display a list of configuration parameters such as:
Exit Tone Enable:
>YES
9. The process may be repeated until all Auxiliary Sirens are
registered.
2.12 Install/Learn Ademco Transmitters
Each BHS-i100 system supports up to 59 total sensors, which
may include Ademco 5800 series transmitters of the following
types:
5808LST Smoke Detector
5800 Motion Sensor
5853 Glassbreak Detector
In order to install the Ademco Transmitters, Grid Extenders must
be installed and the system should be operational. In addition,
the Programmer must be registered and operational. Ademco
Transmitters are RF qualified during the registration process
using the Grid Extender grid network in the customer’s home.
NOTE
You must remove the cover from the Ademco
5800 Motion Sensor before attempting to register
it. The cover can be replaced after the sensor is
successfully registered.
2.12.1 Install The Transmitter
Ademco Transmitters have permanent serial numbers
programmed at the factory. Therefore, the entire Transmitter
may be installed before registration. There are no special
registration messages or identity information exchanged.
Because unique messages are not used, the probability of Cross
Registration is greater. See section 2.9.1 for information on
Cross Registration and be especially alert for the audio
feedback.
2.12.2 Learn The Transmitter
1. Using the Programmer, navigate to “Learn Devices”, then
select one of the following, depending on the type of sensor
you are attempting to register:
“Learn Ademco Sensor”,
“Learn Glass Sensor”,
“Learn Motion Sensor”, or
“Learn Fire Sensor”
Registration will be enabled for 60 seconds only. The
Programmer will display:
Please Fault Sensor
(Note: the actual text displayed will differ slightly depending
on the type of sensor you are attempting to register.)
2. While holding the Programmer near the Ademco
Transmitter (within 1 foot is preferred), fault the sensor.
(Note: The 5808LST Smoke Detector can be faulted by
pressing the recessed test button on the front of the unit.
The 5800 Motion Sensor can be faulted by moving your
hand in front of the sensor. The 5853 Glassbreak Detector
can be faulted by tapping it with a pen.) The sensor will
send a fault transmission and the Programmer will triple
beep. If successful, the Programmer will display:
Sensor detected:
Serial Number:
13444322
1=ACCEPT 2=REJECT
3. If the Transmitter fails to transmit within 60 seconds, the
Programmer will display an error message and leave
registration mode automatically. If a system detects two
different Ademco Transmitter bursts during the Transmitter
registration mode it will not register any Transmitter and the
Programmer will display an error message and leave
registration mode automatically.
4. The registration must be confirmed by faulting the sensor.
The Programmer will then display either:
Sensor (Magnet)
REGISTERED
Press ENTER
to continue
or
Sensor
NOT REGISTERED
Press ENTER
to continue
5. If the sensor fails to qualify, the Programmer will return to
the “Learn Devices” menu.
6. If the Sensor successfully qualifies, the Programmer will
display:
Assign Sensor to
Zone #
> <default>
7. The installer may enter a new number, or press [Enter] to
select the default zone value. If the installer enters a zone
number which is currently in use, the Programmer will
display: