User's Manual

BHS-i100 Installation and Programming Instructions
10
Pressing “2” deregisters the Programmer and causes the
initial registration screen to be displayed.
2.9.4 Learn Additional Keypads
Prior to registering another Keypad to the system, the new
Keypad should be beeping approximately once every 30
seconds to indicate that it contains a factory default
configuration. If the Keypad is not beeping every 30 seconds,
then the Keypad already contains an identity and configuration.
In that case, follow the steps in section 2.9.6 in order to return
the GE to factory default configuration.
For each Keypad to be added to the system:
1. Carry the Programmer to the next Keypad.
2. On the Programmer, navigate to “Learn Devices”, then
“Learn GE”. Registration will be enabled for 60 seconds
only. The Programmer will display:
RSSI: xxxx (Ok|Not Ok)
Press registration
key/button combination
on GE ESC to exit
The RSSI is the Received Signal Strength Indication
showing how strongly the Programmer is receiving the
wireless signal from the Master Keypad. It is a reasonable
estimate of the signal that the new Keypad should also
receive.
3. Press and hold“5”,“6”.. Upon successful registration, the
Programmer and the Keypad will each chirp. The
Programmer will display:
Press 0 on keypad
to test connection
(Programmer beeps)
1=ACCEPT 2=REJECT
4. The Programmer will return to the Learn Devices menu.
2.9.5 Learn Signal Extender(s)
Prior to registering a Grid Extender to the system, the Grid
Extender should be beeping approximately once every 30
seconds to indicate that it contains a factory default
configuration. If the Grid Extender is not beeping every 30
seconds, then the Grid Extender already contains an identity and
configuration. If the installer wants to register a Grid Extender
that already contains an identity, it will be necessary to reset the
Grid Extender to factory default values as described in section
2.9.6.
For each Grid Extender to be added to the system:
1. Carry the Programmer to the Grid Extender.
2. On the Programmer, navigate to “Learn Devices”, then
“Learn GE”. Registration will be enabled for 60 seconds
only. The Programmer will display:
RSSI: xxxx (Ok|Not Ok)
Press registration
key/button combination
on GE ESC to exit
The RSSI is the Received Signal Strength Indication
showing how strongly the Programmer is receiving the
wireless signal from the Master Keypad. It is a reasonable
estimate of the signal that the new Keypad should also
receive.
3. On the Signal Extender, press and hold the button on the
front until the LED flashes. Upon successful registration, the
Programmer and the Grid Extender will each chirp. The
Programmer will display:
Press button on GE
to test connection
(Programmer beeps)
1=ACCEPT 2=REJECT
4. The Programmer will return to the Learn Devices menu.
2.9.6 Resetting A GE To Factory Default
In some instances, a GE may contain an identity and
configuration that prevents the installer from registering a
Keypad or Grid Extender. This will require the device to be
restored to factory default settings before continuing with
registration.
To restore a GE to factory default settings:
1. Disconnect AC power from the outlet which the GE is
plugged into.
2. Remove the battery from the GE.
3. Wait 10 seconds to allow internal power to discharge.
4. Reinstall the battery and within 10 seconds press and hold
the registration button (for Grid Extenders) or press and
hold “5”, “6”.. In either case, the final button/key must be
held until the LED begins to flash and an audible beep is
heard (about 10 seconds).
5. Remove the battery. Wait 10 seconds. Re-install the
battery.
6. Reinstall the GE and restore AC power (following the
instructions in section 2.7).
7. The GE should now beep approximately once every 30
seconds to indicate that it contains a factory default
configuration and is ready to register.
2.9.7 Registration Troubleshooting
Problem: The Programmer is registered into a neighboring
system.
Symptom: Local Keypad doesn’t chirp when attempting to
register the Programmer, or the Programmer fails
to beep when pressing the “0” key on the Keypad
(per step 3. in section 2.9.3 above).
Recovery: If this is an initial installation, repeat the “Set First
Keypad To Master” procedure in section 2.9.2
and “Learn The Programmer” procedure in
section 2.9.3. If this is an existing installation,
following the procedure in section 3.1.3.
Problem: A GE is registered into a neighboring system.
Symptom: Local GE doesn’t chirp when attempting to
register it, and Programmer doesn’t indicate a
successful registration. Or, “GE Finder” fails.
Recovery: Follow the “Resetting a GE To Factory Default”
procedure in section 2.9.6 and then repeat
registration