Installation Guide

12
Moisture Testing: It is the responsibility of the ooring contractor and the installer to conrm all concrete
substrates, both old and new, for moisture transmission using the Calcium Chloride Moisture Test according
to ASTM F-1869. Moisture vapor transmission should not exceed the recommended levels of 8 lbs. or less per
1,000 sq. ft. in 24 hours. This test should be performed and documented prior to installation. A second testing
option determines relative humidity in concrete oor slabs using In-Situ Probes, which should be less than
90% RH per ASTM F-2170 before, during and after installation. These acceptable moisture readings are only
applicable when using iGrip adhesive for sheet vinyl.
PH LEVELS: PH must be between 5 and 9
Inspection of ooring material prior to installation is required. Any defects should be immediately reported
to the retail store from which the ooring was purchased before installation. Tra󰮐cMaster will not be
responsible for labor costs to repair or replace material with defects that were apparent before or noticed at
the end of an installation. The job site and all ooring material and adhesive must be kept for 24 hours before,
during and after installation between 65˚ F and 85˚ F (18°C and 29°C).
PLEASE NOTE: If removal of existing resilient oor covering is required, follow all recommended Resilient Floor
Covering Institute (RFCI) work practices at www.rfci.com.
Light Commercial Installation Guide – Sheet Vinyl Flooring
This document is reviewed on an ongoing basis. 10/10/14
Application
Width x Depth x Spacing
Flooring
Type
Trowel Specications
Roberts Item # Coverage
1/16” x 1/16” x 3/32” U Trowel
1/16” x 1/16” x 1/16” U Trowel
49736 / 10121-12
10-810 / 10-823
10125
Fiberglass
Sheet Goods &
Luxury Vinyl Tile
Fiberglass
Sheet Goods &
Luxury Vinyl Tile
160-180 sq. ft.
per gallon
170-190 sq. ft.
per gallon
PLEASE NOTE: Less porous substrates typically require a smaller notched trowel and longer open time than
porous substrates. Ensure 100% transfer of adhesive to the substrate and the ooring backing.