6.5 MM THICKNESS/22 MIL WEAR LAYER
RIGID CORE DROP-AND-LOCK FLOORING
Product Information
Commercial & Residential Use
Warranty: Lifetime Residential -
20-Year Commerci
al
STANDARDS - SAFETY & PERFORMANCE
Standard Description Requirements Results
ASTM E648
Critical Radiant Flux (Radiant Panel) Class I: ≥ 0.45 W/cm
2
Passes Requirements
1
ASTM E662
Smoke Density Flaming & Non-Flaming ≤ 450 Passes Requirements
2
ASTM D2047
Coefficient of Friction (Slip Resistance) Not Applicable (No Official Requirements) ≥0.6 (Dry)
ASTM F970
Static Load No Requirements if Wear Layer < 20mil Not Applicable
SIM Test
Static Load Limit Test to Limit (±0.005”) ≥500psi
ASTM F2199
Dimensional Stability ≤0.25% / lineal ft. Surpasses Requirements
ASTM F925
Chemical Resistance No more than “Slight Change” Surpasses Requirements
ASTM F1514
Resistance to Heat Average ΔE < 8.0 Surpasses Requirements
ASTM F1515
Resistance to Light Average ΔE < 8.0 Surpasses Requirements
ASTM G21
Antifungal Activity Not Applicable (No Official Requirements) Top: 0-1
ASTM F963
Heavy Metals Refer to Standard Passes Requirements
ASTM D7823
Phthalates Refer to CPSIA4 Passes Requirements
STANDARDS - SOUND
Assembly Results Remarks
6" Concrete Slab
IIC 54
All tested assemblies
pass IBC
5
requirements of
STC ≥ 50 and IIC ≥ 50 for
multi-story dwellings
STC 50
HIIC 57
ΔIIC 23
8" Concrete Slab with Suspended
Ceiling and Isolated Subfloor
IIC Up to 72
STC Up to 61
HIIC Up to 80
ΔIIC Not applicable
Notes
1. ASTM E648 - Critical Radiant Flux (Radiant Panel): Passes Requirements for Class I per International Building Code (IBC) 2018 & NFPA 101 Life Safety Code
2. ASTM E662 - Smoke Density: 450 is the limit established by many state, county, and/or local building and/or fire codes, but is not set as a limit for (resilient) flooring products nationwide. Thus, Smoke
Density requirements for flooring products may vary from jurisdiction to jurisdiction.
3. ASTM G21 - Antifungal Activity: Top Surface (LVT Top Layer) scored 0-1 (No Growth to <10% Growth)
4. CPSIA = Consumer Product Safety Improvement Act
5. IBC = International Building Code
Anti-Microbial Treatment
Clear Wear Layer with Scratch
Resistance
Decorative Pattern
Core Layer
Easy Drop-and-Lock Installation
Sound Mitigating Underlayment