Service Manual

19
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes
DIAGNOSTICS
H O U R S =
12
DIAGNOSTICS STATE 13 - TOTAL HOURS and STATISTICS
Upon entry to this state, TOTAL HOURS are displayed.
STATISTICS can be displayed using the UP and DOWN arrow keys.
The ‘UP ARROW’ allows scrolling through the available programs and shows the number of times each program
has been selected. The ‘DOWN ARROW’ backs up through the list of available programs and back to the total
hours displayed.
To clear the statistics in the EEPROM, hold the DISPLAY LOCK key down while pressing the ENTER key.
The Programs are:
HOUR
HILL
RANDOM
MANUAL
FAT
CARDIO
FIT
WATTS
METS
QUICK
HRT HILL
HRT INT
HRT EXT
SPRT TRN
Pressing the ‘CLEAR/PAUSE’ key will return to DIAGNOSTICS STATE 12.
Pressing the ‘START/ENTER’ key will advance to DIAGNOSTICS STATE 14.
Section II